Brand: KEYENCE
Model: SJ-LM series
Product Name: Compact Nozzle Static Eliminator
Specification:
Model | SJ-L005M | SJ-L005MT |
Type | Nozzle type | Tube type |
Voltage application method | High frequency AC method |
Applied voltage | 2.2 kVAC | 2.5 kVAC |
Ion balance | ±10 V*1 | ±10 V*6 |
Static elimination time | 0.4 sec.*1 | See Data Sheet. |
Air supply pressure | 0.05 to 0.5 MPa |
Air supply temperature | 0 to +50°C |
Connection tube | Outer diameter: ø6, inner diameter: ø4 |
Ozone concentration | 0.05 ppm or less*2 | 0.05 ppm or less*7 |
Control input | Static elimination stop input | Switchable between non-voltage input and voltage input Non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA or lower (short circuit) Voltage input: Maximum input rating 30 V, ON voltage 7 V or higher, OFF current 0.1 mA or lower, ON current 1.5 mA or lower (at 30 V)*3 |
Reset input |
LPC mode input |
Control output | Alarm (N.C.)/Ion level alarm (N.O.) | Open-collector output 30 VDC or less, 50 mA max., residual voltage 1.5 V or less, NPN/PNP settings switchable*3*4 |
Ratings | Power voltage | 24 VDC ±10% (including ripple) or 12 VDC (dedicated AC adapter OP-88020/87722*5) |
Current consumption | 0.2 A or less (24 VDC) 0.3 A or less (12 VDC) |
Environmental resistance | Ambient temperature | 0 to +50°C (0 to +40°C when OP-87722 is used) |
Relative humidity | 35 to 65% RH (no condensation) |
Overvoltage category | I |
Pollution degree | 2 |
Material | Main unit case: PBT / Charge indicator: TPU / Securing bracket: SUS303, PBT Cable: PVC, TPE, copper alloy Connector: PBT, brass + gold plating, phosphor bronze + gold plating, coper alloy + gold plating Fitting: Brass + electroless Ni plating, POM, NBR |
Weight | Approx. 60 g | Approx. 65 g |