Model | CS-151F1 | CS-152F1 | CS-150F1 |
Target of measurement | SC-1 (ammonia/hydrogen peroxide aqueous solution) | SC-2 (hydrochloric acid/hydrogen peroxide aqueous solution) | SPM (sulfuric acid/hydrogen peroxide aqueous solution) |
Multi-monitoring with one unit of up to 4 types of chemical solutions or ranges possible. |
Measurement principle | Absorption spectrometry |
Concentration computation principle | Temperature-compensated multivariate analysis |
Measurement range (mass %) | NH3: 0.00% to 1.00% H2O2: 0.00% to 5.00% H2O: 94.0% to 100.0% | HCI: 0.00% to 2.00% H2O2: 0.00% to 2.00% H2O: 96.0% to 100.0% | H2SO4: 70.0% to 96.0% H2O2: 0.00% to 10.00% H2O: 4.0% to 30.0% |
Repeatability (mass %) (within ±1% room temperature) | NH3: ±0.15% H2O2: ±0.30% H2O: ±1.5% | HCI: ±0.15% H2O2: ±0.15 % H2O: ±1.5% | H2SO4: ±0.50% H2O2: ±0.50% H2O: ±1.5% |
・Repeatability for the list above is for the cell unit type.Please contact us for the repeatability of the in-line cell type. ・Differences in the above list may occur depending on measurement range.(Please see our website for details.) |
Sample solution temperature | 20 to 80: (when using Inline cell) 20 to 30: (when using cell unit) |
Measurement cycle | Approx. 3 seconds |
Content of LCD and input | • 1st component: measured concentration value (%) •Error code • 2nd component: measured concentration value (%) •Parallel concentration alarm output invalid status • 3rd component: measured concentration value (%) •Serial/parallel status • 1st and 2nd components: concentration alarm status •Background compensation data |
RS-232C serial input | • Serial/parallel status switching •Parallel concentration alarm output status • Measurement data transfer request (valid/invalid) • 1st and 2nd component concentration alarm setting •Target measurement solution switching |
Parallel input | 12 to 30 V DC (photocoupler insulated) • Parallel concentration alarm output • Target measurement solution switching • Background compensation |
Parallel output | Open collector output (photocoupler insulated) • 1st component concentration alarm, 4 types Max. current when on: • 2nd component concentration alarm, 4 types DC 5 mA (no internal protection resistor) • Device error Max. impressed voltage when off: 30 V DC • Measuring • Target measurement solution type • Background compensation status |
Solution temperature input | Terminal block connection (M3 terminal screws) • Platinum resistance temperature sensor: Pt100 (Pt100 sensor should be prepared by customers) |
Analog output | • 1st component concentration alarm, 4 types: 4 to 20 mA • 2nd component concentration alarm, 4 types: 4 to 20 mA ✽We also support other measurement ranges. Please specify when ordering. |