Model | LR-ZB250C3P*1 |
Type | Distance based laser sensor |
Shape | Rectangular |
Output | PNP |
Cable connection | M8 connector, 3-pin |
Detectable distance | 35 to 250 mm (215 to 0)*2 |
Standard detectable deviation | 35 to 180 mm: 9 mm 180 to 250 mm: 25 mm |
Display resolution | 1 to 3 (1 to 3 mm) |
Spot diameter | Approx. 2.4 × 1.2 mm at 250 mm |
Response time | 1.5 ms / 10 ms / 50 ms selectable |
Light source | Type | Red laser (660 nm) |
Laser class | Class 1 laser product (IEC60825-1, FDA (CDRH) Part1040.10*3) |
Function | Indicator | 3-digit 7-segment display (red), output indicator (yellow), DATUM indicator (orange), 1 spot indicator (green) |
Timer | OFF/ON delay/OFF delay/One-shot |
Rating | Power voltage | 10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS |
Power consumption | 450 mW or less (18 mA or less at 24 V, 34 mA or less at 12V) |
Specifications | Control output | PNP Open collector, Applied voltage 30 VDC or less, Control current 100 mA or less, Residual voltage 1.2 V or less at 10 mA or less, 2 V or less at 10 to 100 mA |
Protection circuit | Protection against reverse power connection, output overcurrent, output surge, reverse output connection |
Output operation | Light-ON / Dark-ON selectable |
Environmental resistance | Enclosure rating | IP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X, 6P, 13 (NEMA250), ECOLAB*4, Diversey*4 |
Insulation resistance | 20 MΩ or more (500 VDC) |
Ambient light | Incandescent lamp: 2,000 lux or less Sunlight: 4,000 lux or less*5 |
Ambient temperature | -10 to +50 °C (No freezing) |
Storage temperature | -25 to +75 °C (No freezing) |
Relative humidity | 35 to 85 % RH (No condensation) |
Withstand voltage | 1,000 VAC, 50/60 Hz, 1 min |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions |
Shock resistance | 1,000 m/s2, 6 times in each of the X, Y, and Z directions |
Material | Case: SUS316L, Display: PES, Lens cover: PMMA with scratch-resistant coating, Packing/Connector ring: FKM |
Accessories | Instruction Manual, Certification/Identification label (FDA) |
Weight | Approx. 55 g |
*1 M8 connector (3-pin) type does not include the external input function. *2 Display readings can be used as a guide for the detecting distance. When the setting value is tuned, the readout shifts. When the value exceeds "-99", "-FF" is displayed. *3 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50. *4 Have passed resistance tests with cleaning agents from multiple manufactures. *5 When the response time is 10 ms |