Model | LR-ZH500P*1 |
Type | U.C.D. Function Distance based laser sensor |
Shape | Rectangular |
Output | PNP |
Cable connection | 2 m cable |
Detectable distance | 35 to 500 mm (465 to 0)*2 |
Standard detectable deviation | 35 to 180 mm: 9 mm 180 to 300 mm: 25 mm 300 to 400 mm: 40 mm 400 to 500 mm: 50 mm |
Display resolution | 1 to 5 (1 to 5 mm) |
Spot diameter | Approx. ø3 mm |
Response time | 1.5 ms / 10 ms / 50 ms selectable |
Light source | Type | Red laser (660 nm) |
Laser class | Class 2 laser product (IEC60825-1) Class II Laser product (FDA (CDRH) Part1040.10) |
Function | Indicator | 3-digit 7-segment display (white), output indicator (yellow), DATUM indicator (orange), 1 spot indicator (green) |
Timer | OFF/ON delay/OFF delay/One-shot |
Rating | Power voltage | 10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS |
Power consumption | 450 mW or less (18 mA or less at 24 V, 34 mA or less at 12 V) |
Specifications | Control output | PNP Open collector, Applied voltage 30 VDC or less, Control current 100 mA or less, Residual voltage 1.2 V or less at 10 mA or less, 2 V or less at 10 to 100 mA |
Protection circuit | Protection against reverse power connection, output overcurrent, output surge, reverse output connection |
Output operation | Light-ON / Dark-ON selectable |
External input | Input time calibration: 35 ms or more ON, 35 ms or more OFF Laser emission stop: 2 ms or more ON, 20 ms or more OFF Short-circuit current NPN: 1 mA or less/PNP: 2 mA or less |
Environmental resistance | Enclosure rating | IP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X, 6P, 13 (NEMA250), ECOLAB*3, Diversey*3 |
Insulation resistance | 20 MΩ or more (500 VDC) |
Ambient light | Incandescent lamp: 10,000 lux or less Sunlight: 20,000 lux or less at 250 mm*4 Incandescent lamp: 2,000 lux or less Sunlight: 4,000 lux or less at 500 mm*4 |
Ambient temperature | -10 to +50 °C (No freezing) |
Storage temperature | -25 to +75 °C (No freezing) |
Relative humidity | 35 to 85 % RH (No condensation) |
Withstand voltage | 1,000 VAC, 50/60 Hz, 1 min |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions |
Shock resistance | 1,000 m/s2, 6 times in each of the X, Y, and Z directions |
Material | Case: SUS316L, Display: PES, Lens cover: PMMA with scratch-resistant coating, Packing/Connector ring: FKM |
Accessories | Instruction Manual, FDA warning/certification/identification label, Laser warning/explanation labels |
Weight | Approx. 110 g (Including cable) |
*1 IO-Link specification v.1.1/COM2 (38.4 kbps) is supported. You can download a setup file from the KEYENCE website. If using the product in an environment in which downloading files over the internet is not possible, contact your nearest KEYENCE office. *2 Display readings can be used as a guide for the detecting distance. When the setting value is tuned, the readout shifts. When the value exceeds "-99", "-FF" is displayed. *3 Have passed resistance tests with cleaning agents from multiple manufactures. *4 When the response time is 10 ms |