Product name | Resistivity meter |
Model | HE-200R |
Combined sensor | 2-electrode method resistivity sensor (ERF-001 Series) of cell constant 0.01/cm |
Measuring range | Resistivity | MΩ•cm | 0.000 to 2.000 | 0.00 to 20.00 (*Note 1) |
kΩ•cm | 0.00 to 20.00 | 0.0 to 200.0 (*Note 1) |
Temperature | ℃ | 0℃ to 100℃ (Display range: −10℃ to 110℃) |
Display resolution | Resistivity | As shown in the measuring table. |
Temperature | 0.01℃ |
Performance | Resistivity | Repeatability | Within ±0.1% of the full scale (response for equivalent input) |
Linearity | Within ±0.5% of the full scale (response for equivalent input) |
Temperature | Repeatability | ±0.1℃ (response for equivalent input) |
Linearity | ±0.5℃ (response for equivalent input) |
Transmission output | Number of output | 2 (The negative terminals for transmission outputs are internally connected at the same electric potential) |
Output type | 4 mA to 20 mA DC: input/output isolated type |
Load resistance | Maximum: 900Ω |
Linearity | Within ±0.08 mA (output only) |
Repeatability | Within ±0.02 mA (output only) |
Output range | Output 1 | Resistivity: Free setting within a measuring range. |
Output 2 | Temperature: Free setting within a range between −20 and 130℃ |
Occasional out for error | Hold or burnout to either 3.8 mA or 21 mA |
Transmission hold | In the maintenance mode, transmission signal is held at the latest value or preset value. In the calibration mode, transmission signal can be alive or held. |
Contact output | Number of output | 3 |
Output type | No-voltage contact output |
Contact type | Relay contact; SPDT (1c) |
Contact capacity | 250 V AC, 3 A; 30 V DC, 3 A (resistance load) |
Contact function | R1, R2 | Selectable from upper limit alarm, lower limit alarm, and currently holding of transmission output. (The contact is closed during alarm operation, opened normally and while the power is down.) |
FAIL | Error alarm (Closed in the normal state, opened in the failure state or while the power is down.) |
Alarm setting range | |
Contact input | Number of input points | 1 |
Contact type | No-voltage "a" contact for open collector |
Conditions | ON resistance: 100 Ω max. Open voltage: 24 V DC Short-circuit current: 12 mA DC max. |
Contact function | External input for transmission holding. |
Transmission capability | Method | RS-485 |
Signal type | 2 wire system, isolated from the input circuit Not isolated from transmission circuit |
Temperature compensation | Applicable temperature element | Platinum resistor: 1 kΩ (0℃) |
Compensation method | Temperature characteristic of NaCl (reference temperature: 5℃ to 95℃) Arbitrary temperature coefficient input (reference temperature: 5℃ to 95℃; temperature coefficient: +/−3%/℃) No temperature compensation One of the three ways of compensation is selectable. (In the de-ionized water area, the temperature compensation for pure water is automatically performed in both NaCl and arbitrary temperature coefficient compensation settings.)
|
Temperature compensation range | 0℃ to 100℃ (However, the compensation calculation is extended lower than 0℃ or higher than 100℃.) |
Calibration | Resistivity | Based on parameter input of coefficient for the sensor cell constant. |
Temperature | Comparison to the accurate thermometer Both deviation and coefficient of RTD are taken into account for calibration. |
Other function | UPW standard resistivity input | Select one from the next. 182.3 kΩ•m (standard), 181.8 kΩ•m, 182.4 kΩ•m, 18.23 MΩ•cm (standard), 18.18 MΩ•cm, or 18.24 MΩ•cm |
Clipping function | If the measured value exceeds the user setting value for clipping, the measured data will be held at the clipping value. |
Self-check | Sensor diagnostic error | Temperature sensor short-circuit, temperature sensor disconnection, and out of the temperature measurement range |
Converter error | CPU, ADC, and memory errors |
Operating temperature range | −20℃ to 55℃ (without freeze) |
Operating humidity range | Relative humidity: 5% to 90% (without condensation) |
Storage temperature | −25℃ to 65℃ |
Power supply | Rated power supply voltage | 100 V to 240 V AC ±10% 50/60 Hz |
Power consumption | 15 VA (max) |
Other | With power switch for maintenance use |
Compatible standards | CE marking | EMC :EN61326-1 Class A, Industrial electromagnetic environment Safety :EN61010-1 RoHS :EN50581 9. Industrial monitoring and control instruments |
FCC rules | Part15 Class A |
Structure | Installation | Outdoor installation type |
Installation method | Mount on 50 A pole or wall |
Protection code | IP65 |
Case material | Aluminum alloy (coated with epoxy-denatured melamine resin) |
Material of fittings | SUS304 |
Material of hood | SUS304 stainless steel (coated with epoxy denatured melamine resin) |
Material of window | Polycarbonate |
Display element | Reflective monochrome LCD |
External dimensions | 180 (W) mm × 155 (H) mm × 115 (D) mm (excluding cover and mounting brackets) |
Mass | Main body: Approx. 3.5 kg; cover and mounting brackets: Approx. 1 kg |