Model | AP-N10D |
Type | Dual output type |
Applicable sensor head | AP-41M, AP-41, AP-43, AP-44, AP-48 |
Configuration/Display range | -15 to +110 % of F.S. |
Repeatability | ±0.2 % of F.S. |
Display resolution | AP-41M/41/44/48: Standard mode 0.1 kPa, High resolution mode 0.01 kPa AP-43: Standard mode 0.001 MPa, High resolution mode 0.1 kPa |
Power consumption | Normal | 770 mW or less (at 24 V, 32 mA or less/at 12 V, 54 mA or less) |
Expansion units | Max. 16 units (Dual output type is counted as 2 units.)*1 |
Control output(s) | 2*2 |
Display temperature characteristic | ±1 % of F.S. (When the temperature varies from 25 °C) |
Response time (Chattering prevention function) | 1 ms/2.5 ms/5 ms/100 ms/500 ms/1,000 ms/5,000 ms selectable |
Rating | Power voltage | 12 to 24 VDC ±10 %, Ripple (P-P) 10 % max. Class2 |
Power consumption | Eco mode | 560 mW or less (at 24 V, 23 mA or less/at 12 V, 37 mA or less) |
Environmental resistance | Ambient temperature | 0 to +50 °C (No freezing)*3 |
Relative humidity | 35 to 85 % RH (No condensation) |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions |
Shock resistance | 500 m/s2, 3 times in each of the X, Y, and Z directions |
Material | Main unit and cover: Polycarbonate |
Weight | Approx. 20 g |
*1 Can connect to other N-bus sensor amplifiers. N-bus represents the wire-saving system for KEYENCE-manufactured sensor amplifiers. *2 Number of outputs when connected to the communication unit NU-Series. There are no control output wires. *3 11 to 16 units connected: 0 to +45 °C (When the sensor amplifier is installed on DIN rail on a metal plate) |