Product name | ORP meter |
Model | HO-300 |
Combined sensor | ORP electrode |
Measurable range | ORP | −2000 mV to 2000 mV (display range: −2200 mV to 2200 mV) |
Temperature | 0℃ to 100℃ |
Display resolution | ORP | 1 mV |
Temperature | 0.1℃ |
Performance | ORP | Repeatability | Within ±5mV (response for equivalent input) |
Linearity | Within ±5mV (response for equivalent input) |
Temperature | Repeatability | ±0.3℃ (response for equivalent input) |
Linearity | ±0.3℃ (response for equivalent input) |
Transmission output | Output type | 4 mA to 20 mA DC: input/output insulation type |
Load resistance | Max.: 600Ω (case of 24 V DC power supply)*1 |
Linearity | Within ±0.08 mA (output only) |
Repeatability | Within ±0.02 mA (output only) |
Output range | ORP: Selection from preset ranges or free range input within measuring range. |
Occasional out for error | Hold or burnout to either 3.8 mA or 21 mA |
Transmission hold | In the maintenance mode, transmission signal is held at the latest value or preset value. In the calibration mode, transmission signal can be alive or held. |
Contact input | Number of input points | 1 |
Contact type | No-voltage a-contact |
Conditions | ON resistance: 40 Ω Open voltage: 1.2 V Short-circuit current: 21 mA DC max. |
Contact function | External input for transmission holding. |
Temperature measurement | Applicable temperature element | Platinum resistor: 1 kΩ (0℃) |
Positive relation resistor with temperature: 500 Ω (25℃), 6.8 kΩ (25℃), 10 kΩ (25℃) |
Element selection method | Automatic temperature sensor type detection or manual selection (no temperature element is selectable) |
Calibration | ORP adjust function | Adjust (offset adjustment): −200 mV to 200 mV Span sensitivity correction: 0.500 to 1.500 |
Temperature calibration | 1 point calibration comparing reference thermometer |
Self-check | Calibration error | Temperature calibration error Out of temperature calibration range (for ORP sensor with RTD). |
Electrode diagnostic error | Reference electrode impedance error (only applicable for differential circuit mode with a liquid contact electrode) Temperature sensor short-circuit, temperature sensor disconnection, and out of the temperature measurement range |
Converter error | CPU, ADC, and memory errors |