HORIBA HU-200TB-W Field-installation type turbidity meter

HORIBAHU-200TB-WField-installation type turbidity meterSpecifications:Product nameTurbidity meterModelHU-200TB-W Industrial-use turbidity converterTurbidity sensortypeSS-120-W Industrial-use turbidity

  • model:

HORIBA

HU-200TB-W

Field-installation type turbidity meter


Specifications:

Product name

Turbidity meter

Model

HU-200TB-W Industrial-use turbidity converter

Turbidity sensor
type

SS-120-W Industrial-use turbidity detector

Measurement range

Kaolin

0 to 1000 (degrees) (Display range: 0 to 1100 (degrees)) or 0 to 1000 (mg/L)

Formazin

0 to 2000 (Display range: 0 to 2200 )

PSL

0 to 100 (degrees) (Display range: 0 to 110 (degrees))

Transmission output
setting range

Kaolin

Arbitrary setting within the range from 0.00 to 10.00 (degrees), 0.0 to 100.0
(degrees), 0 to 2200 (degrees)

Formazin (NTU)

PSL

Display resolution

  • 0.01 degrees (Degree range: 0 to 10 (degrees))

  • 0.1 degrees (Degree range: 0 to 100 (degrees))

  • 1 degrees (Degree range: 100 to 2200 (degrees))
    Selectable between fixed range (decimal point) and automatic range changeover

Performance

Repeatability

Within ±2% of the reading or ±0.04 degrees, whichever is larger (checked using the solid span bottle)

Linearity

The deviation at the mid-range point of the span calibration value is within ±2% of the span calibration value or ±0.04 degrees, whichever is larger

Accuracy

Within ±2% of reading

Transmission output

Number of current outputs:2

Output type

4 mA to 20 mA DC, input/output isolation type

Load resistance

900 Ω (max.)

Linearity

Within ±0.08 mA (limited to the current linearity)

Repeatability

Within ±0.02 mA (limited to the current repeatability)

Error output

Provided with burnout function (3.8 mA or 21 mA)

Hold function

Selectable between the latest value hold and the preset value hold

Contact output

Number of output points: 6

Output type

No-voltage output contact

R1, R2

Contact type

Relay contact, SPST (1a)

Contact capacity

250 V AC 3 A, 30 V DC 3 A (resistance load)

Contact function

Selectable from among the upper limit alarm, lower limit alarm, during transmission output hold, cleaning output and automatic calibration (closed at alarm operation, open under normal conditions and in a power-off state)

Description of alarm

  • Setting range: Within turbidity measurement range

  • Delay time: 0 to 600 (s)

R3

Contact type

Relay contact, SPST (1a)

Contact capacity

30 V DC 1 A (resistance load)

Contact function

Selectable from among the upper limit alarm, lower limit alarm, during transmission output hold, cleaning output and automatic calibration (closed at alarm operation, open under normal conditions and in a power-off state)

Description of alarm

  • Setting range: Within turbidity measurement range

  • Delay time: 0 to 600 (s)

FAIL

Contact type

Relay contact, SPDT (1c)

Contact capacity

250 V AC 3 A, 30 V DC 3 A (resistance load)

Contact function
Error alarm (closed under normal condition, open in an error or power-off state)

Description of alarm

  • Error alarms for values outside the measurement range,
    self-checks, and calibration errors can be set

  • Delay time: 0 to 600 (s)

RANG1,
RANG2

Contact type

Relay contact, SPST (1a)

Contact capacity

30 V DC 1 A (resistance load)

Contact function

Status output of the transmission output range

Control output for
automatic zero
calibration (ZERO
OUT, SAMPLE
OUT)

Number of output points

2

Output type

Voltage contact output (connection power supply voltage output)

Contact capacity

250 V AC 0.5 A

Contact function

SAMPLE OUT: Electric ball valve control output
ZERO OUT: Solenoid valve control output

Contact input

Number of input points

4

Contact type

Open collector no-voltage “a” contact

Condition

ON resistance: 100 Ω max.
Open-circuit voltage: 24 V DC
Short-circuit current: 12 mA DC max.

Contact
function

EXT1

Switchable between automatic zero calibration command and transmission hold

EXT2

Switchable between cleaning command and transmission hold

EXT3, EXT4

Selection command from four ranges using 2-bit contacts

Communication
function

Type

RS-485

Signal form

Two wire type, the power source of the communication is isolated from the power of measurement circuit. (The power source of transmission and communication are not isolated.)

Calibration

Calibration method

Zero calibration

By filtered clean water

Automatic zero
calibration

Zero calibration is performed automatically by switching to the filtered clean water (option)

Span calibration

Turbidity adjustment method by coefficient input

Compatible standard substances

Kaolin, Formazin (NTU), PSL