HORIBA

HORIBA LabRAM Odyssey Nano AFM-Raman for physical and chemical imaging

HORIBALabRAM Odyssey NanoAFM-Raman for physical and chemical imagingSpecifications:SmartSPM Scanner and BaseSample scanning range: 100 µm x 100 µm x 15 µm (±10 %)Scanning type by sample: XY non-linear

  • model:

HORIBA

LabRAM Odyssey Nano

AFM-Raman for physical and chemical imaging


Specifications:

SmartSPM Scanner and Base

Sample scanning range: 100 µm x 100 µm x 15 µm (±10 %)

Scanning type by sample: XY non-linearity 0.05 %; Z non-linearity 0.05 %

Noise: 0.1 nm RMS in XY dimension in 200 Hz bandwidth with capacitance sensors on; 0.02 nm RMS in XY dimension in 100 Hz bandwidth with capacitance sensors off; < 0.04 nm RMS Z capacitance sensor in 1000 Hz bandwidth

Resonance frequency: XY: 7 kHz (unloaded); Z: 15 kHz (unloaded)

X, Y, Z movement: Digital closed loop control for X, Y, Z axes; Motorized Z approach range 18 mm

Sample size: Maximum 40 x 50 mm, 15 mm thickness

Sample positioning: Motorized sample positioning range 5 x 5 mm

Positioning resolution: 1 µm

AFM Head

Laser wavelength: 1300 nm, non-interfering with spectroscopic detector

Registration system noise: Down to < 0.1 nm

Alignment: Fully automated cantilever and photodiode alignment

Probe access: Free access to the probe for additional external manipulators and probes

SPM Measuring Modes

Contact AFM in air/(liquid optional); Semicontact AFM in air/(liquid optional); Non -contact AFM; Phase imaging; Lateral Force Microscopy (LFM); Force Modulation; Conductive AFM (optional); Magnetic Force Microscopy (MFM); Kelvin Probe (Surface Potential Microscopy, SKM, KPFM); Capacitance and Electric Force Microscopy (EFM); Force curve measurement; Piezo Response Force Microscopy (PFM); Nanolithography; Nanomanipulation; STM (optional); Photocurrent Mapping (optional); Volt-ampere characteristic measurements (optional)

Spectroscopy Modes

Confocal Raman, Fluorescence and Photoluminescence imaging and spectroscopy

Tip-Enhanced Raman Spectroscopy (TERS) in AFM, STM, and shear force modes

Tip-EnhancedPhotoluminescence (TEPL)

Near-field Optical Scanning Microscopy and Spectroscopy (NSOM/SNOM)

Conductive AFM Unit (optional)

Current range:  100 fA ÷ 10 µA; 3 current ranges (1 nA, 100 nA and 10 µA) switchable from the software

Optical Access

Capability to use simultaneously top and side plan apochromat objective: Up to 100x, NA = 0.7 from top or side; Up to 20x and 100x simultaneously

Closed loop piezo objective scanner for ultra stable long term spectroscopic laser alignment: Range 20 µm x 20 µm x 15 µm; Resolution: 1 nm

Spectrometer

Fully automated high resolution LabRAM Odyssey micro-spectrometer, functional as stand-alone micro-Raman microscope