KEYENCE PX-10CP Amplifier Unit, Connector Type, PNP

KEYENCEPX-10CPAmplifier Unit, Connector Type, PNPSpecifications:ModelPX-10CPTypeConnector typeOutputPNPResponse time500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)Output selectionLIGHT-ON/DAR

  • model:

KEYENCE

PX-10CP

Amplifier Unit, Connector Type, PNP


Specifications:

Model

PX-10CP

Type

Connector type

Output

PNP

Response time

500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)

Output selection

LIGHT-ON/DARK-ON

Indicator lamp

- Operation indicatorRed LED x 2, DSC orange LED x 1
- Dual digital monitorDual 7-segment display
[Preset value (4-digit green LED) and current value (4-digit red LED) illuminated together,
current value range0 to 65504, excess gain0 P to 999 P]
- Hold functionPossible to display both peak and bottom hold values. Selectable from 5 variations.
- Bar LED monitor [Excess gain displayed (85% to 115% in 7 steps)]
- Scaling display

Detection mode

Light intensity (automatic sensitivity-tracking function provided)/ [Limit light intensity/output monitor]

Shift function

Variable between –1999 and 9999

Timer function

Timer OFF/OFF-delay/ON-delay/One-shot/ON-delay, OFF-delay/ON-delay, One-shot
Timer duration selectable1 ms to 9999 ms
Maximum error against the setting value10% max.

Control output

PNP open-collector 30 V, 100 mA max. for an output/100 mA max. for two outputs, residual voltage 1 V max.

External input

Interference prevention

Up to 4 units (in all power modes)*1

Rating

Power voltage

12 to 24 VDC, Ripple (P-P) 10 % or less, Class 2*2

Power consumption

Standard mode50 mA max. at 24 V/55 mA max. at 12 V
Power saving mode40 mA max. at 24 V/45 mA max. at 12 V

Environmental resistance

Enclosure rating

IEC: IP67/JEM: IP67/NEMA: 4X

Ambient temperature

-10 to +55 °C (No freezing)*3

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

Case material

HousingPBT, displayPSU, display cover/connector coverSUS304, radiator plateSUS304, gasketNBR

Weight

Approx. 50 g

*1 The received light intensity may vary somewhat when the sensor head's cable layout is changed, so redo the sensitivity setting when changing the layout. The interference prevention function is affected
somewhat when using multiple units installed adjacent to each other. Fine-tune the sensitivity (increase the setting) for adjacent layouts.
*2 Use a 24 VDC power voltage when using a head light transmitting cable of 3 m or more (PX-H71/H71TZ) or 10 m or more (PX-H72).
*3 When using multiple units connected adjacently, the ambient temperature varies with the conditions below.
2 to 4 Units: -10 to +50 °C, 5 to 17 Units: -10 to +45 °C.