Model | LR-WF10C |
Type | Fiber Type M12 connector 4-pin type |
Detecting distance | Detecting Distance and Min. Spot Diameter Based on Attached Fiber Head |
Min. spot diameter |
Light source | White LED |
Mutual interference reduction function | Up to 2 units when alternate frequencies set |
Timer | OFF/ON delay/OFF delay/One-shot |
Response time | 250 µs, 1 ms, 10 ms, 100 ms, 500 ms Selectable*1*2 |
I/O | Control output | NPN open collector/PNP open collector selectable 30 VDC or less, 50 mA or less, remaining voltage: 2 V or less N.O./N.C. selectable *3 |
External input | Tuning /Transmission OFF selectable Short circuit current: 1 mA or less for NPN/2 mA or less for PNP For the applied voltage, see the wiring diagrams in the instruction manual. For the input times, see the time charts in the instruction manual. *4 |
Protection circuit | Protection against reverse power connection, power supply surge, output overcurrent, output surge, and reverse output connection |
Power supply | Power voltage | 10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS |
Current consumption | 50 mA or less (without load) at 24 VDC; 90 mA or less (without load) at 12 VDC*5 |
Environmental resistance | Enclosure rating | IP65 (IEC60529)*6*7 |
Ambient light | Incandescent lamp: 10,000 lux or less, Sunlight: 20,000 lux or less |
Ambient temperature | -20 to +45 °C (No freezing) |
Relative humidity | 35 to 85 % RH (No condensation) |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions |
Shock resistance | 1,000 m/s2, 6 times in each of the X, Y, and Z directions |
Material | Case: Zinc die cast (Nickel chrome plating), Indicator cover: PPSU, Buttons: PES, Display: PMMA (scratch-resistant coating), Connector ring: PMP, Connector socket: PEI, Fiber locking mount: PBT, NBR, Silicone rubber, SUS304, SUSXM7 Adapter: PBT |
Weight | Approx. 95 g |
*1 When alternate frequencies are set, the response time increases by approximately 20%. *2 When using the IO-Link communication, if the response time is set in 1ms or more, it becomes approximately 10% slower. *3 IO-Link: Specification v.1.1/COM2 (38.4 kbps) is supported. The setup file can be downloaded from KEYENCE website (http://www.keyence.com).If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office. *4 IO-Link: Specification v.1.1/COM2 (38.4 kbps) is supported. The setup file can be downloaded from KEYENCE website (http://www.keyence.com). If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office. *5 160 mA or less (at 10 V, with load) *6 When the following small-diameter fiber units (the diameter of the cable is ø1.3 or ø1.0) are used, the IP65 rating cannot be satisfied (FU-4F/66/91/93/43/63/63T etc.). When any small-diameter fiber units except for the above are used, IP65 is applied. *7 When the waterproof adapter A/B are not used at the time of installation of a small-diameter fiber unit, the IP65 enclosure rating cannot be satisfied. |