SONIC GF-2500 GF-2500 Steam FEX-100 Flame-proof Ultrasonic Gas Flow Meter

SONICGF-2500 GF-2500 Steam FEX-100 Flame-proofUltrasonic Gas Flow MeterSpecification:■Ultrasonic Gas Flowmeter GF SeriesGF-2500PipeFluid conditionGasApplicable pipe diameterNominal diameter 50mm~5000m

  • model:

SONIC

GF-2500 GF-2500 Steam FEX-100 Flame-proof

Ultrasonic Gas Flow Meter


Specification:

■Ultrasonic Gas Flowmeter GF Series

GF-2500

Pipe

Fluid condition

Gas

Applicable pipe diameter

Nominal diameter 50mm5000mm (*1)

Spool piece

Pipe diameter

50mm500mm (*2)

Flange

JIS10k standard (*3)

Material

SGPSUS304  --- (*4)

Socket

Standard type

Screw type
Flange type (Screw  type with sensor)
Flange type (Large  senor type)

Sensor

Installation requirement

Upper stream side 15D,Lower stream side 5D or more (D is inner diameter)

Sensor probe

Gas・・・Standard (screw type)

nominal diameter 50mm500mm(*5)
temperature -30℃180 ℃
pressure -0.05Pa1MPa  (-0.5 10kgf/cm )

Large(flange type)

nominal diameter 500mm(*5)
temperature -30℃180 ℃
pressure -0.05Pa1MPa  (-0.5 10kgf/cm )

Seal

Probe fittings

Combine with gas seal unit

Gas seal unit

standard, large, custom

Gas seal adaptor

instead of gas seal unit (not used)

Cable

Distance from sensor probe to converter, 6m or 10m (standard)

Converter

General

Measurement method

Ultrasonic transit time method

Chordal path

1 path or 2 path (option)

Traverse

Z or V

Measurement compensation range

temperature +/-25℃, pressure +/- 30%

Accuracy

± 1.0% FS (flow velocity 5 60m/s)

Reproducibility

±0.2%

Flow velocity resolution

less than 0.5mm/s

Averaging

Default 10 sec (0 180 sec variable)

Ultrasonic thermometer

Measure temperature (in case of air) by ultrasound transit time

Ambient temperature

-10+50℃

Power supply

Power supply

AC100V±10%, 50/60Hz, AC115V, 220V (option)

Surge protection

Built-in surge absorber

Power dissipation

Max.25(W)

Output

Analog output1

Various flow output,DC420mA, isolated
Over range: DC024mA                                            Load resistance: Less than 1000Ω

Analog output2

Various flow output,reverse flow, temperature, pressure

Range: DC420mA,isolated

Over range: DC024mA

Load resistance: Less than 1000Ω

Pulse output1

Integrated pulse
Open collector standard 30V, 0.2A
Pulse width: 1.6ms or 50ms

Pulse output2

AIntegrate pulse, alarm, normal and reverse flow, upper l and lower limit
Open collector standard 30V, 0.2A

Pulse output3

Alarm, normal and reverse flow, upper l and lower limit
Open collector standard 30V, 0.2A

Pulse output4

Alarm, normal and reverse flow, upper l and lower limit
Open collector standard 30V, 0.25A

Power supply for pressure and temperature

DC24V+/-0.5V  0.2A

Digital output

RS422×1  RS232C×1

Input

temperature

DC420mA

Pressure

DC420mA

Display

LCD

128 x 240 dots LED back right

Character

Alphanumeric, mathematical symbol (ex, +, -, Σ)

Display contents

Measurement display
Instantaneous flow rate (analog1,2)
Integrated count (analog1,2)
Max flow rate (analog1,2)
Input temperature, pressure,
ultrasonic temperature meter
It can display content of 4  in all contents.

Configuration view

diameter, temperature, pressure, flow range

Adjustment view

zero point adjusting, change of time constant, low-cut

*1 : Consult sales representative if used over 2000mm.
*2 : Consult sales representative if used over 500mm.
*3 : Consult sales representative if used any flanges other than JIS10k
*4 : Consult sales representative if used any materials other than those above
*5 : Applicable gas to measure depends on density, temperature, pressure and velocity.

■Ultrasonic Gas Flowmeter GF Series for Steam

GF-2500S

Pipe

Fluid condition

Steamsaturated

Applicable pipe diameter

Nominal diameter 50mm400mm

Spool piece

Pipe diameter

50mm400mm

Flange

JIS10k standard

Material

SGP

Socket

JIS10k 40A FF

Installation requirement

Upper stream side 15D,Lower stream side 5D or more (D is inner diameter)

Sensor

Sensor probe

Applicable temperature

Saturated steam of less than 183.3 ℃

Applicable pressure

1MPa

Seal

Protect pipe

Combine with FTR-701A

Cable

Distance from sensor probe to converter, 6m or 10m (standard)

Converter

General

Measurement method

Ultrasonic transit time method

Accuracy

± 1.0% FS (flow velocity 5 60m/s)

Reproducibility

±0.2%

Flow velocity resolution

less than 0.5mm/s

Averaging

Default 10 sec (0 180 sec variable)

Power supply

Power supply

AC100V±10%, 50/60Hz, AC115V, 220V (option)

Power dissipation

Max.25(W)

Output

Analog output (2 lines):

DC4 20mA Load resistance : less than 1000Ω

Pulse output (4 lines)

Open collector standard 30V, 0.25V

Power supply for pressure

DC24V+/-0.5V  0.2A

Digital output

RS422×1  RS232C×1

Input

Pressure

DC420mA

Display

LCD

128 x 240 dots LED back right

■Ultrasonic Gas Flowmeter GF Series for Explosion-proof

FEX-100

Pipe

Fluid condition

Gas

Applicable pipe diameter

Nominal diameter 50mm5000mm (*1)

Spool piece

Pipe diameter

50mm500mm (*2)

Flange

JIS10k standard (*3)

Material

SGPSUS304 --- (*4)

Sensor

Sensor probe

Gas・・・Standard (screw type)

nominal diameter 50mm500mm(*5)
temperature -30℃180 ℃
pressure -0.05Pa1MPa  (-0.5 10kgf/cm )

Large(flange type)

nominal diameter 500mm(*5)
temperature -30℃180 ℃
pressure -0.05Pa1MPa  (-0.5 10kgf/cm )

Flame-proof standard

ExdⅡBT4

Seal

Gas seal unit

standard, large, custom

Installation requirement

Upper stream side 15D,Lower stream side 5D or more (D is inner diameter)

Cable

Distance from sensor probe to converter, 6m or 10m (standard)

Converter

General

Measurement method

Ultrasonic transit time method

Chordal path

1 path or 2 path (option)

Traverse

Z or V

Accuracy

± 1.0% FS (flow velocity 5 60m/s)

Reproducibility

±0.2%

Flow velocity resolution

less than 0.5mm/s

Averaging

Default 10 sec (0 180 sec variable)

Ultrasonic thermometer

Measure temperature (in case of air) by ultrasound transit time

Ambient temperature

-10+50℃

Power supply

Power supply

AC100V±10%, 50/60Hz, AC115V, 220V (option)

Power dissipation

Max.25(W)

Surge protection

Built-in surge absorber

Output

Analog output (2 lines):

DC4 20mA Load resistance : less than 1000Ω

Pulse output (4 lines)

Open collector standard 30V, 0.25V

Power supply for pressure

DC24V+/-0.5V  0.2A

Digital output

RS422×1  RS232C×1

Input

temperature

DC420mA

Pressure

DC420mA

Display

LCD

128 x 240 dots LED back right

Character

Alphanumeric, mathematical symbol (ex, +, -, Σ)

Display contents

Measurement display
Instantaneous flow rate (analog1,2)
Integrated count (analog1,2)
Max flow rate (analog1,2)
Input temperature, pressure,
ultrasonic temperature meter
It can display content of 4  in all contents.

Configuration view

diameter, temperature, pressure, flow range

Adjustment view

zero point adjusting, change of time constant, low-cut

Flam e-proof standard

ExdⅡBT6

*1 : Consult sales representative if used over 2000mm.
*2 : Consult sales representative if used over 500mm.
*3 : Consult sales representative if used any flanges other than JIS10k
*4 : Consult sales representative if used any materials other than those above
*5 : Applicable gas to measure depends on density, temperature, pressure and velocity.