ESCO
EA708D-3A.
Clamp meter (digital mini)
Specifications:
Manufacturer | Sanwa Electric Instruments (sanwa) | Model number | DCL31DR. |
Current measurement method | CT clamping method | Operation method | Δ-Σ method |
AC wave detection method | True effective value method (TrueRMS) | Range switching | Auto |
Usage environment conditions | Altitude 2000m or less, indoor, environmental pollution level II | Operating temperature and humidity | 0℃ to 30℃, 80% RH or less (no condensation) 31℃ to 40℃, linearly reduced from 80% RH to 50%RH |
Storage temperature and humidity | -10℃ to 50℃, 70% RH or less (no condensation) | Guaranteed range of accuracy | 23±5℃, 80% R.H. Below (no condensation) |
Direct current and alternating current | 60/400A ●The highest accuracy (AC) ±(2%rdg+5dgt) 50/60Hz (DC) ±(2.0%rdg+10dgt) Accuracy after setting the zero point (DC+AC) ±(2.5%rdg+10dgt) 50/60Hz ±(3.5%rdg+15dgt) ※45~400Hz (other than 50/60Hz) ●Resolution: 0.01A | Sample rate | About 2 times/second About 1 time/second ※DC+AC mode |