Manufacturer | Sanwa Electric Instruments (sanwa) | Model number | PDM5219S. |
Rated voltage | 125V/250V/500V | Rated resistance | 100 MΩ |
Measuring range | Rated voltage 125V: 0.02 to 0.1 to 50 to 100MΩ 250V: 0.02~0.1~50~100MΩ 500V: 0.02~0.1~50~100MΩ ●Tolerance: ±5% of the indicated value (First effective measurement range: 0.1 to 50) ±10% of the indicated value (Second effective measurement range: other than the first effective measurement range above) | Insulation resistance | 125V/250V/500V Maximum scale: 100MΩ The first effective scale: 0.1M-50MΩ |
DC voltage | 0 to 60V Tolerance: Within ±5% of the maximum scale value | AC voltage | 0 to 600V Tolerance: Within ±5% of the maximum scale value (sine wave alternating current: 50 to 60Hz) |
AC rectification method | Semi-wave rectification method (Average value indication effective value conversion) | Meter specification | Endomagnetic toteband method, 48 μA |
Battery depletion display | CHECK AT THE BATTERY CHECK RANGE | Tolerance guaranteed temperature and humidity range | 23±5℃ 75%RH or less (No condensation) |
Temperature and humidity range used | 0 to 43℃ 80%RH or less (No condensation) | Storage temperature and humidity range | -10 to 50℃ 70%RH or less (No condensation) |
Posture | Horizontal ±5° | External magnetic field | None |
Built-in battery voltage | Within the scope of validity | Usage environment conditions | Altitude 2000m or less Environmental pollution level II |
Rated measurement current | Within 1 to 1.2 mA | Maximum power consumption | About 2.6W |
Measurable number of times | 500 times (5 seconds ON/25 seconds OFF) | Power supply | 6LF22/6LR61 (9V alkaline battery) x 1 |
Size | 99(W)x43(D)×144(H)mm | Weight | About 310g (main body) |
Function | ●Discharge function ●Inner battery check function ●AC voltage measurement function ●Lock function of rated printing switch (continuous measurement) | IP protection grade | IP20 (measurement probe installed) |