Model | FS-N40 |
Type | Zero Line |
Main unit/expansion unit | Expansion unit |
Response time | 23 µs (S-HSPD*1) / 50 µs (HSPD*2) / 250 µs (FINE) /500 µs (TURBO) / 1 ms (SUPER) / 4 ms (ULTRA) / 16 ms (MEGA) / 64 ms (TERA) |
Number of control outputs | None*3 |
Light source LED | Transmitter side: Red, four-element LED (wavelength 660 nm) |
External input | Input time 2 ms (ON) / 20 ms (OFF) or longer*4 |
Unit expansion | Up to 16 units (17 units connected in total including the main unit). However, each dual output type will be treated as two expansion units. |
Protection circuit | Protection against reverse power connection, output overcurrent, output surge, and reverse output connection |
Mutual interference prevention | S-HSPD/HSPD 0 units, FINE 4 units, TURBO/SUPER/ULTRA/MEGA/TERA 8 units (The mutual interference prevention values are twice those shown here when Double is set.) |
Power supply | Power voltage | 10 to 30 VDC (including 10% ripple (P-P) or less) , class 2 or LPS*5 |
Current consumption | During normal operation: 870 mW or less (34 mA or less at 24 V/62 mA or less at 12 V) ECO ON: 800 mW or less (31 mA or less at 24 V/56 mA or less at 12 V) ECO FULL: 710 mW or less (28 mA or less at 24 V/49 mA or less at 12 V)*6 |
Environmental resistance | Ambient light | Incandescent lamp: 20,000 lux or less, sunlight: 30,000 lux or less |
Ambient temperature | -20 °C to +55 °C (no freezing)*7 |
Vibration resistance | 10 to 55 Hz; double amplitude 1.5 mm; 2 hours each for X, Y, and Z axes |
Shock resistance | 500 m/s2 ; 3 times each for X, Y, and Z axes |
Case material | Main unit and cover: polycarbonate |
Weight | Approx. 23 g |
*1 Restrictions when S-HSPD is selected Area detection, Area % Mode, DATUM, Rising edge, and Falling edge cannot be selected for Detection Mode. Output timer, Limit Detection, and Display Gain cannot be used. FULL cannot be selected for the ECO function. *2 Restrictions when HSPD is selected Display Gain cannot be used. *3 This counts as 1 output when connecting multiple units to the FS-MC8N/P, NU Series. *4 The input time becomes 25 ms (ON)/25 ms (OFF) when external calibration input is selected. *5 When expanding the system to 9 or more units, use a power supply voltage of 12 V or higher. *6 The load current is excluded. The power consumption including the load when the maximum number of units are connected is 38 W max. *7 When expanded by 1 to 2 units: -20 °C to +55 °C. When expanded by 3 to 10 units: -20 °C to +50 °C. When expanded by 11 to 16 units: -20 °C to +45 °C. When using 2 outputs, 1 unit is counted as 2 units. The prescribed values for the ambient temperature assume that the sensor amplifier has been mounted on a DIN rail installed on a metal surface. Exercise special care when installing the product in an airtight space. |