KEYENCE

KEYENCE IL-1050 Amplifier unit, DIN-rail mount type

KEYENCEIL-1050Amplifier unit, DIN-rail mount typeSpecifications:ModelIL-1050TypeDIN-rail mountMain unit/Expansion unitExpansion unitHead compatibilityCompatibleDisplayMinimumdisplayable unitIL-S025/IL

  • model:

KEYENCE

IL-1050

Amplifier unit, DIN-rail mount type


Specifications:

Model

IL-1050

Type

DIN-rail mount

Main unit/Expansion unit

Expansion unit

Head compatibility

Compatible

Display

Minimum
displayable unit

IL-S025/IL-030: 1 µm, IL-S065/IL-065/IL-100: 2 µm, IL-300: 10 µm, IL-600: 50 µm

Display range

IL-S025/IL-030/IL-S065/IL-065/IL-100: ±99.999 mm to ±99 mm (4 levels selectable),
IL-300/IL-600: ±999.99 mm to ±999 mm (3 levels selectable)

Display rate

Approx. 10 times/sec.

Analogue voltage output

None

Analogue current output

Control input

Bank switch input

Non-voltage input*1

Zero-shift input

Stop emission input

Timing input

Reset input

Control output

Judgment output

Open collector output (NPN, PNP changeover possible/N.O., N.C. changeover possible)*2

Alarm output

Open collector output (NPN, PNP changeover possible/N.C.)*2

Current

Power voltage

Supplied by main unit*3

Power consumption

2000 mW or less (at 30 V: 67 mA or less)

Environmental resistance

Pollution degree

2

Ambient temperature

-10 to +50 °C (No condensation or freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

Material

Case / Front sheet: Polycarbonate; Key tops: Polyacetel; Cable: PVC

Weight

Approx. 140 g (including attachments)

*1 Assign an input of your choice to the 4 external input lines before using.
*2 The NPN open collector rated output is: 50 mA max./ch (20 mA when adding an expansion unit) less than 30 V, residual voltage less than 1 V (less than 1.5 V when adding over 6 units including the main unit)
The PNP open collector rated output is: 50 mA max./ch (20 mA/ch when adding expansion units), less than power voltage, and less than 2 V residual voltage (less than 2.5 V when adding over 6 units including the main unit)
*3 If there are over 6 additional expansion units, please use a power voltage of 20 to 30 V.