Models | NTB-500C, control software DCS-100A (Standard accessory) NTB-500C-0, control software DCS-100A (Optional accessory) |
Mountable Measuring Units | [Model: NTB-50C] Name: Strain Unit Terminal block type: One-touch type
[Model: NTB-51C] Name: Voltage/Thermocouple Unit Terminal block type: Soldering, screwing type |
Measuring Targets and Measuring Units | [Strain Unit NTB-50C] Strain gages, strain-gage transducers Quarter bridge 120 Ω 2-wire system Quarter bridge 120 Ω 3-wire system Half bridge 120 to 1000 Ω Active-active system Full bridge 120 to 1000 Ω
[Voltage/Thermocouple Unit NTB-51C] Voltage ±10.0000 V Voltage ±50.000 V Temperature Thermocouples K(CA) Temperature Thermocouples T(CC)
*You are not able to combine with the NTB-50A, NTB-50B, NTB-51A. |
Channels | Max. 8/unit Mixed combination of up to 2 measuring units (4 channels/unit) possible |
Synchronous Operation | Max. 8 units, 64 channels The NTB-500C can connect with the NTB-500A. |
Automated Measurement Functions | Able to preset the measuring conditions by using the Measurement Condition Setting Software. Able to output the CAN data after turning ON the power. There is no data synchronization between measuring instruments. |
Sampling Frequencies | 1, 2, 5, 10, 20, 50, 100, 200, 500, 1000 Hz Synchronous sampling of all channels.
Sampling frequencies (Hz): 1 k Cable length = 20 m: 8 Cable length = 80 m: 4 Cable length = 100 m: ー Cable length = 400 m: ー
Sampling frequencies (Hz): 500 Cable length = 20 m: 16 Cable length = 80 m: 8 Cable length = 100 m: 4 Cable length = 400 m: ー
Sampling frequencies (Hz): 200 Cable length = 20 m: 40 Cable length = 80 m: 20 Cable length = 100 m: 8 Cable length = 400 m: 4
Sampling frequencies (Hz): 100 Cable length = 20 m: 64 Cable length = 80 m: 40 Cable length = 100 m: 20 Cable length = 400 m: 8
Sampling frequencies (Hz): 50 Cable length = 20 m: 64 Cable length = 80 m: 64 Cable length = 100 m: 40 Cable length = 400 m: 20
Sampling frequencies (Hz): 20 to 1 Cable length = 20 m: 64 Cable length = 80 m: 64 Cable length = 100 m: 64 Cable length = 400 m: 64
*Make sure the firmware version is 01.05 or later for using the communication cable length 400 m. |
Cable Length | Total extended cable length, max. 400 m |
TEDS | When NTB-50C installed Reads information from TEDS-installed sensors. Channel name writing (If the manufacturer's ID is Kyowa) |
Interfaces | Bosch 2.0B active support (ISO-11898 specifications-compliant high-speed CAN) |
Data Save | Measurement data is saved on a PC. (No internal storage) |
Operating Temperature | -10 to 50 ºC |
Operating Humidity | 20 to 85% (Non-condensing) |
Power Supply | 11 to 16 VDC |
Current Consumption (When using 12 VDC) | [With 2 NTB-50C installed] Stand-by: 200 mA or less Measuring: 230 mA or less
[With 2 NTB-51C installed] Stand-by: 250 mA or less Measuring: 300 mA or less |
Dimensions | 175 W × 28.7 H × 106.4 D mm (Excluding protrusions) |
Weight | Approx. 490 g |
Compliance | Directive 2014/30/EU (EMC) Directive 2011/65/EU, (EU)2015/863 (10 restricted substances) (RoHS) |
|