KYOWA

KYOWA WGA-680A Instrumentation Amplifier Instrumentation Amplifier

KYOWAWGA-680A Instrumentation AmplifierInstrumentation AmplifierSpecifications:ModelsWGA-680A-00: AC model No optionWGA-680A-01: AC model BCD & TEDS WGA-680A-02: AC model RS-232C & TEDS WGA-68

  • model:

KYOWA

WGA-680A Instrumentation Amplifier

Instrumentation Amplifier




Specifications:

Models

WGA-680A-00: AC model No option
WGA-680A-01: AC model BCD & TEDS
WGA-680A-02: AC model RS-232C & TEDS
WGA-680A-03: AC model RS-485 & TEDS
WGA-680A-04: AC model CC-Link

WGA-680A-10: DC model No option
WGA-680A-11: DC model BCD & TEDS
WGA-680A-12: DC model RS-232C & TEDS
WGA-680A-13: DC model RS-485 & TEDS
WGA-680A-14: DC model CC-Link

Channels

1

Applicable Sensors

Strain-gage transducers (4-wire)

Compatible Bridge Resistance

87.5 to 1000 Ω
(Up to four 350 Ω transducers connected in parallel.)

Bridge Excitation

10, 2 VDC, selectable

Measuring Range

±3.2 mV/V (Input range including zero adjustment range)

Zero Adjustment Range

Within measurement range
(Not retained when power supply interrupted)

Nonlinearity

Within ±(0.02% FS +1digit)

Stability

Zero point: Within ±0.25 μVRTI/ºC
Sensitivity: Within ±0.01%/ºC

Sampling Speed

4000 times/s

AD Resolution

24 bits

Calibration

Actual load calibration
Sensitivity registering calibration
Numeric value registering calibration

Smoothing Functions

Analog Filters: 10, 30, 100, 300 Hz
Attenuation: -12 ±1 dB/oct.
Moving average: 0, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1024, and 2048 times
Min. scale: 1, 2, 5, 10, 20, 50, 100, 200, 500, and 1000 counts

Auto Zero Compensation

Zero Tracking (Auto digital zero in the preset range)

Approximated zero compensation:
Indication is made zero when the reading is in a preset range of 0 to 9.

Adding Functions

Setting range: ±99999

Original Value Display Functions

±3.2000 mV/V (5 digits)
Accuracy: Within ±0.1%FS

Comparator Functions

Points: 4

Patterns:
Registers 4 groups of pattern files (comparative values) and enables switching through setting of functions

Types:
 Extra high (HH)
 High (HI)
 Low (LO)
 Extra low (LL)

Setting range: ±99999

Hysteresis: 0 to 99999

Comparison modes: Normal, at hold

High low assignment:
Enables assigning high or low to each comparator.

Judgement Function

Point: 1

Type: OK

Hold Functions

Digital peak/bottom hold (Without analog peak/bottom hold)

Types:
 Arbitrary point hold
 Peak hold
 Bottom hold
 Peak to peak hold
 Interval definition peak hold
 Time specification peak hold
 Interval definition peak to peak hold
 Time specification peak to peak hold

Delay time: 0.00 to 9.99 s

Detect time: 0.01 to 9.99 s

Display

Range: ±99999 (Decimal point to be put anywhere.)

Indicator: 7-segment LED
Character height: 14 mm
Colors: Red, green, and orange

Update: 0.12, 0.24, 0.49, 0.98, 1.95, 3.90, 7.80, and 15.6 times/s
(In normal mode)

Modes: Normal/hold

Comparators: 5 points (HH, HI, OK, LO, LL)

Status: 2 points (HOLD, LOCK)

Analog (DA) Output

Voltage output: ±10 V (Load resistance 2 k Ω or more)
Arbitrary scaling possible

Current output: 4 to 20 mA (Load resistance 500 Ω or less)
Corresponds to voltage output of 0 to 10 V.

Conversion speed: 4000 times/s

Nonlinearity: Within ±0.1%FS

Setting contents: Display value of zero, display value of full scale

Control Input

Points: 3

Types: Zero command, hold command, and reset command

Signal formats: Non-voltage contact signal or open collector (NPN)
 (Capacity: 12 VDC, 5 mA or more)

Control Output

Points: 5

Types: HH, HI, OK, LO, and LL

Formats: Open collector (NPN) (30 VDC, 20 mA max.)

Level Test Functions

Display of arbitrary values possible

Display additional functions: Disabled, enabled

Setting range: ±99999

Level test: ON, OFF

Power Supply

AC Models
 100 to 240 VAC, power consumption: 20 VA or less

DC Models
 10 to 30 VDC, power consumption: 10 W or less

Dimensions

96 W ×96 H ×126 D mm (Excluding protrusions)

Weight

Approx. 750 g (Without option)

Operating Temperature

-10 to 50 ºC

Operating Humidity

20 to 80% (Non-condensing)

Compliance

Directive 2014/30/EU (EMC)
Directive 2014/35/EU (LVD) (AC model only)
Directive 2011/65/EU, (EU) 2015/863 (10 restricted substances) (RoHS)