Channels | 1 |
Applicable Transducers | Strain-gage transducers |
Compatible Bridge Resistance | 87.5 to 1000 Ω (350 Ω, 4 in parallel connection) |
Bridge Excitation | 2 VDC, 10 VDC, switchable |
Measuring Range | ±3.2 mV/V (Including zero adjustment range) |
Zero Adjustment Range | Within measuring range (Not retained when power supply interrupted) |
Sampling Speed | 2000 times/s |
Resolution | 64000 counts/input range in both polarities |
Calibration Functions | Actual load calibration Sensitivity registration calibration Numerical value registration calibration |
Display Functions | Main display: 5 digits (±99999), polar LED
Sub display: 1 digit (9)
Update speed: 0.13, 0.25, 0.51, 1.02, 2.03, 4.07, 8.16, and 16.28 s (Thinning display)
Comparative determination: 3 points (HIGH, OK, LOW)
Status display: 2 points (HOLD, LOCK) |
Nonlinearity | Within ±(0.02%FS ±1 digit) |
Stability | Zero point: ±0.25 μV RTI /ºC Sensitivity: ±0.01%/ºC |
Smoothing Functions | Minimum scale : 1, 2, 5, 10, 20, 50, and 100 counts Moving average : 0, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1024, and 2024 times Filters : 10, 30, 100 Hz and FLAT |
Comparison/Judgment Functions | Comparators : 2 points (HIGH, LOW) Hysteresis : Individual width settings possible Comparison mode : Normal/at hold Judgment : 1 point |
Pattern Functions | Registers 4 groups of pattern files (comparative values) and enables switching through setting of functions. |
Adding Functions | Setting range: ±99999 |
Original Value Display Functions | ±3.20000 mV/V (6 digits) Accuracy: ±0.1%FS |
Level Test Functions | Display of arbitrary values possible |
Hold Functions | Digital peak hold Arbitrary point hold Peak hold Section definition hold Time specification hold Time specification continuous peak hold |
Analog Output | Simultaneous dual output of voltage & current
Data update: 2000/s (For simultaneous use of voltage and current, 1000/s)
Voltage output: ±10 V, independent arbitrary scaling possible
Current output: 4 to 20 mA, independent arbitrary scaling possible Automatic settings with rated capacity fully scaled possible (At sensitivity registration, at automatic sensitivity registration)
Nonlinearity: Within ±0.1%FS |
TEDS | Automatic sensitivity registration by reading TEDS data Automatic sensitivity registration by reading TEDS files |
Control Input | 4 points: Zero command Level test command Hold command Reset command |
Control Output | 3 points: HIGH OK LOW |
Operating Temperature | -10 to 50°C |
Operating Humidity | 20 to 85% |
Power Supply | 100 to 240 VAC, 22 VA or less |
Dimensions | 96 W × 48 H ×144 D mm |
Panel-cut Dimensions | 92.2+0.4/-0mm W ×45.2+0.4/-0mm H Plate thickness 0.8 to 5.0 mm recommended |
Weight | Approx. 400 g |