KYOWA

KYOWA WD-100A Indicator for Voltage-Output Type Sensors Indicator for Voltage-Output Type Sensors

KYOWAWD-100A Indicator for Voltage-Output Type SensorsIndicator for Voltage-Output Type SensorsSpecifications:Measurement Channel2Display2.4 inch TFT LCDAch measurement result, Bch measurement result,

  • model:

KYOWA

WD-100A Indicator for Voltage-Output Type Sensors

Indicator for Voltage-Output Type Sensors


Specifications:

Measurement Channel

2

Display

2.4 inch TFT LCD
Ach measurement result, Bch measurement result, calculation result,
Ach and Bch measurement results,
Ach or Bch measurement result and calculation result

Over Warning

OVER or -OVER when display range are exceeded

External Controls

Following 5 functions can be assigned to control terminals (user-configurable).
Comparator reset function
Totalized value reset function
Measurement prohibited function:
 Measurement prohibited A/B/A&B
Current value hold function:
 Current value hold A/B/A&B
Max value hold function:
 Max value hold A/B/A&B
Min value hold function:
 Min value hold A/B/A&B
Digital zero function
Pattern change function:
 Pattern change 1 to 3
Display change function
Trend hold function
As follows, only shortcut setting
Compare list function

Operating Temp & Humidity Range

-5 to 50°C, 35 to 85% (No condensation)

Storage Temp & Humidity Range

-10 to 70°C, 60% or less

Power Supply

24 to 48 VDC ±10%

Power Consumption

6 W max. at 24 VDC,
6.5 W max. at 48 VDC

Sensor Power Supply

12 VDC ±10% 100 mA max.;
24 VDC ±10% 50mA max.
*When 2 channel input, allowable current of Ach and Bch together will be above current.
*1.2 W max. when the combination of 12 VDC and 24 VDC.

Dimensions

96 mm (W) × 52 mm (H) × 145 mm (D)

Weight

Approx. 350 g

Withstand Voltage

1500 VAC for 1 minute: Between the power supply terminal-input /
external control / comparator output / option output

1500 VAC for 1 minute: Between the input terminal-external control /
comparator output / option output

3000 VAC for 1 minute: Between enclosures-each terminals

Insulation Resistance

500 VDC 100 MΩ or more between the above terminals

Vibration Tolerance

10 to 55 Hz half amplitude 0.15 mm in X, Y, Z directions for 30 minutes

Protection

IP66
(When mounted on the panel. See outline drawing for coverage.)

Installation Environment

Indoor use

Applicable EN Standard

EN61326-1
 (EMS: Industrial installations; EMI: Class A)
 Applies to wire length of 30 m or less
EN IEC 63000

Case Material

Polycarbonate (PC), Black UL94V-0