Measuring Targets | Strain gages Strain-gage transducers (A separate bridge box is necessary.) |
Channels | 1 |
Compatible Bridge Resistance | 60 to 1000 Ω |
Gage Factor | 2.00 fixed |
Bridge Excitation | 2 Vrms |
Balance Adjustment | Resistance: Within ±2% (±10 k ×10-6 strain) Capacitance: Within 2000 pF (Bridge resistance 120 Ω) |
Balance Adjustment Methods | Resistance: Auto balance Accuracy: Within ±0.5 ×10-6 strain (When 5 V output to 100 ×10-6 strain input) Capacitance: CST (Capacitance self-tracking) |
Frequency Response | DC to 5 kHz (Deviation: ±10%) |
Carrier Frequencies | 12 kHz |
Nonlinearity | Within ±0.2% FS |
Calibration (CAL) | ±(1 to 9999 ×10-6 strain) Accuracy: Within ±(0.5% +0.5 ×10-6 strain) |
Sensitivity Adjustment | Sensitivity is set in combination with a 4-digit INPUT switch and a 3-digit OUTPUT switch.
OUTPUT switch range: 1.00 to 5.00 V in 0.01-V step INPUT switch range: 100 to 9999 ×10-6 strain in 1×10-6 strain step Accuracy: Within ±(0.5% +5 mV) Range: ×200 to ×50000 |
Fine Sensitivity Adjustment | ×0.4 to ×1 |
LPF | Transfer characteristic : 2nd order Butterworth Cutoff frequencies : 10, 30, 100, 300, 1 k Hz and FLAT (6 steps) Amplitude ratio at cutoff point : -3 ±1 dB Attenuation : (-12 ±1) dB/oct. (Except set at 1 kHz.) |
HPF | Cutoff frequencies : 0.2 Hz, OFF (2 steps) |
SN Ratio | Conditions: When 200 ×10-6 strain input and 5 V output, 120 Ω short. DPM-92A: ≥ 45 dBp-p |
Stability | Temperature Zero point: Within ±0.1×10-6 strain per ºC Sensitivity: Within ±0.05% / ºC
Time Zero point: Within ±1 ×10-6 strain per 8 h Sensitivity: Within ±0.3% / 8 h
(When 100 ×10-6 strain input and 5 V output, zero point is measured by 120 Ω short, sensitivity is measured by 120 Ω bridge.) |
Output | Dual output, both BNC connector and integrated connector output the same signal
Voltage output: ±5 V, when load resistance 5 kΩ or more Zero adjustment: -0.1 to 0.1 V |
Output Off Function | Available |
Output Impedance | 2 Ω or less |
Withstand Voltage | 500 VAC for 1 min, between the following two positions respectively: Input and output Input and case Output and case |
Over Input Indication | LED lights up. |
TEDS | Reads the sensor's TEDS information then sets the rated output to OUTPUT switch as output voltage. |
Input Open Detection Function | Saturates output in the negative direction when input is open. |
Connector Type | Input connector : NDIS4102 (7 pins) connector Output connector : BNC connector |
Dimensions | 24 W × 96 H ×170 D mm (Excluding protrusions) |
Weight | Approx. 190 g |
Compliance | Directive 2011/65/EU, (EU) 2015/863 (10 restricted substances) (RoHS) |
|