KYOWA

KYOWA DIS-70A Control Software for Crash Test

KYOWADIS-70A Control Software for Crash TestSpecifications:Applicable ModelsDIS-7200 Series: DIS-7200AS, DIS-724AS,DIS-716AS, DIS-708AS, DIA-708ASDIS-7000 Series: DIS-7000A, DIS-724A, DIA-708A, DIC-70

  • model:

KYOWA

DIS-70A Control Software for Crash Test


Specifications:

Applicable Models

DIS-7200 Series:
DIS-7200AS, DIS-724AS,DIS-716AS, DIS-708AS, DIA-708AS
DIS-7000 Series:
DIS-7000A, DIS-724A, DIA-708A, DIC-706B
DIS-600 Series:
DIS-61A, DIS-632A, DIS-618A
DIS-500 Series:
DIS-506A
DIS-5000 Series:
DIS-5010A, DIS-5000A, DIS-5200A,DIS-5210A, DIA-512A
Other Series:
DIS-3000B/A, DIS-3200B/A,DIS-2000A
*Note that abbreviated model may appear on the DIS-70A.

Number of Controllable Units*1

DIS-7200 & DIS-7000 Series: 4 groups
1 group: 1 unit of DIS-7200A or DIS-7000A
15 units of DIS-724AS, DIS-716AS, DIS-708AS, DIA-708AS, DIS-724A, DIA-708A, DIC-706B

Other than the DIS-7200 & DIS-7000 Series: 1 group
1 group: 16 units of DIS Series
2 units of DIA-512A

Test Conditions Setting Items

Test number, test name, test mode, test objective,
test laboratory, test performer, test comment,
test date, test time, temperature (degree C),
collision angle (degree), collision velocity (km/h),
vehicle model, vehicle number, spec., body type,
engine type, transmission type, vehicle weight (kg)

Channel Conditions Setting Items

DIS series:
Test object, target group, target name,seat position, digital filter, polarity,
ISO MME code, sensor type, sensor model,serial number, sensor ID, rated capacity,rated output (or sensitivity), engineering unit,bridge excitation, bridge resistance,expected value (gain or range)*2, coefficient,offset, balance, comment
DIA series:
ON/OFF, test object, seat position, target name,ISO MME code, delay time, output current,output time, resistance,lower limited resistance before test,upper limited resistance before test,lower limited resistance after test,and upper limited resistance after test

CAN Port Condition Setting Items

DIC Series:
ON/OFF, port label, termination resistor, communication speed, comment

Reading Sensor Information*3

TEDS, sensor ID, sensor files

Measurement Condition Setting Items*4

Sampling frequency
Analog filter
Trigger mode
Pre-trigger time
Post-trigger time
External trigger
Cascade trigger
Analog (level) trigger
Delay time of trigger output


首页
产品
新闻
联系