Power rating | 240 W | 480 W | 960 W |
Output voltage (VDC) | 24 V | 24 V | 24 V |
Efficiency *1 | Three-phase 200 VAC input | 93% typ. | 94% typ. | 95% typ. |
Single-phase/ two-phase 200 VAC input | 92% typ. | 93% typ. | 94% typ. |
Three-phase 230 VAC input | 93% typ. | 94% typ. | 95% typ. |
Single-phase/ two-phase 230 VAC input | 93% typ. | 94% typ. | 95% typ. |
Input con- ditions | Input voltage range *2 | Three-phase/single-phase/two-phase 170 to 264 VAC, 265 to 300 VAC (1 second) 240 to 350 VDC |
Frequency *2 | 50/60 Hz (47 to 63 Hz) |
Input current *1 | Three-phase 200 VAC input | 0.80 A typ. | 1.6 A typ. | 3.1 A typ. |
Single-phase/ two-phase 200 VAC input | 1.4 A typ. | 2.6 A typ. | 5.2 A typ. |
Three-phase 230 VAC input | 0.70 A typ. | 1.4 A typ. | 2.7 A typ. |
Single-phase/ two-phase 230 VAC input | 1.2 A typ. | 2.3 A typ. | 4.5 A typ. |
Power factor *1 | 0.9 min. |
Leakage current *3 | Three-phase 200 VAC input | 1 mA max. |
Three-phase 230 VAC input | 1 mA max. |
Inrush current *4 (for a cold start at 25°C) | Three-phase 200 VAC input | 13 A typ. | 13 A typ. | 14 A typ. |
Three-phase 230 VAC input | 15 A typ. | 15 A typ. | 16 A typ. |
Output character- istics | Rated output current | 10 A | 20 A | 40 A |
Power Boost Function | 15 A | 30 A | 60 A |
Voltage adjustment range *5 | 24 to 29.5 V (with V.ADJ) | 24 to 28 V (with V.ADJ) |
Ripple noise voltage *6 | Three-phase 200 to 240 VAC input | 50 mVp-p max. at 20 MHz of bandwidth | 120 mVp-p max. at 20 MHz of bandwidth | 60 mVp-p max. at 20 MHz of bandwidth |
Input variation influence *7 | 0.5% max. |
Load variation influence *8 | 1.5% max. |
Temperature variation influence | 200 to 240 VAC input | 0.05%/°C max. |
Startup time *9 | Three-phase 200 VAC input | 1,000 ms max. |
Three-phase 230 VAC input | 1,000 ms max. |
Output hold time *9 | Three-phase 200 VAC input | 35 ms typ. | 30 ms typ. | 25 ms typ. |
Three-phase 230 VAC input | 35 ms typ. | 30 ms typ. | 25 ms typ. |
Additional functions | Overload protection | Yes, automatic reset, intermittent operation type Refer to Overload Protection below. |
Overload protection for terminals | No |
Overvoltage protection | Yes, 130% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again), Refer to Overvoltage Protection below. |
Series operation | Yes (For up to two Power Supplies; external diodes required.) |
Parallel operation | Yes (For up to two Power Supplies), Refer to Parallel Operation on Data sheet. |
INPUT OK Indicator | Yes (LED: Green) |
DC OK Indicator | Yes (LED: Green) |
Iout > 100% Indicator | Yes (LED: Yellow) |
DC OK Signal Output | Yes (MOS FET relay output 30 VDC max., 50 mA max.) |
Iout > 100% signal output | Yes (MOS FET relay output 30 VDC max., 50 mA max.) |
Insulation | Withstand voltage | 3.0 kVAC for 1 min. (between all input terminals and all output terminals, signal output terminals), cutoff current 20 mA |
2.0 kVAC for 1 min. (between all input terminals and PE terminals), cutoff current 20 mA |
1.0 kVAC for 1 min. (between all output terminals, signal output terminals and PE terminals), cutoff current 25 mA (240 W/480 W/960 W) 1.0 kVAC for 1 min. (between all output terminals, signal output terminals and PE terminals), cutoff current 40 mA (2000 W) |
0.5 kVAC for 1 min. (between all output terminals and all signal output terminals), cutoff current 10 mA |
Insulation resistance | 100 MΩ min. (between all output terminals, signal output terminals and all input terminals / PE terminals) at 500 VDC |
Environ- ment | Ambient operating temperature *10 | -40 to 70°C (Derating is required according to the temperature. Refer to Engineering Data on Data sheet.) (with no condensation or icing) |
Storage temperature | -40 to 85°C (with no condensation or icing) |
Ambient operating humidity | 95% max. (Storage humidity: 95% max.) |
Vibration resistance *11 | 10 to 55 Hz, maximum 5 G, 0.42 mm single amplitude for 2 h each in X, Y, and Z directions |
Shock resistance *11 | 294 m/s2, 3 times each in ±X, ±Y, ±Z directions |
Reliability | MTBF *12 | 290,000 hrs typ. | 230,000 hrs typ. | 170,000 hrs typ |
Expected life *13 | 10 years min. |
Construc- tion | Weight | 800 g max. | 1,050 g max. | 1,750 g max. |
Cooling fan | No |
Degree of protection | IP20 by EN/IEC 60529 |
Standards | Harmonic current emissions | Conforms to EN 61000-3-2 (single-phase, two-phase *14) Complies with JIS C 61000-3-2 (single-phase, two-phase, three-phase) |
EMI | Conducted emissions | Conforms to EN 61204-3 Class B, EN 55011 Class B (three-phase) Conforms to EN 61204-3 Class A, EN 55011 Class A (single-phase, two-phase) | Conforms to EN 61204-3 Class B, EN 55011 Class (three-phase) Conforms to EN 61204-3 Class B, EN 55011 Class (single-phase, two-phase *16) Conforms to EN 61204-3 Class EN 55011 Class A (single-phase, two-phase) |
Radiated emissions |
EMS | Conforms to EN 61204-3 high severity levels |
Safety standards | • UL 508 (Listing) • CSA C22.2 No.107.1 (cUL) • UL 62368-1 (Recognition) OVC II (≤ 3000 m) Pol2 • CSA C22.2 No.62368-1 (cUR) OVC II (≤ 3000 m) Pol2 • EN/IEC 62477-1 OVC III (≤ 2000 m) OVC II (2000 m < and ≤ 3000 m) Pol2 • EN/IEC 62368-1 OVC II (≤ 3000 m) Pol2 • RCM (EN61000-6-4) • Complies with PELV (EN/IEC 60204-1) • Complies with EN/IEC 61558-2-16 |
SEMI | Complies with SEMI F47-0706 (three-phase / single-phase / two-phase 200 to 240 VAC input) |
Power rating | 2000 W |
Output voltage (VDC) | 24 V | 48 V |
Efficiency *1 | Three-phase 200 VAC input | 95% typ. | 96% typ. |
Single-phase/ two-phase 200 VAC input | 95% typ. | 95% typ. |
Three-phase 230 VAC input | 96% typ. | 96% typ. |
Single-phase/ two-phase 230 VAC input | 95% typ. | 96% typ. |
Input con- ditions | Input voltage range *2 | Three-phase/single-phase/two-phase 170 to 264 VAC, 265 to 300 VAC (1 second) 240 to 384 VDC |
Frequency *2 | 50/60 Hz (47 to 63 Hz) |
Input current *1 | Three-phase 200 VAC input | 6.5 A typ. | 6.9 A typ. |
Single-phase/ two-phase 200 VAC input | 11 A typ. | 12 A typ. |
Three-phase 230 VAC input | 5.7 A typ. | 6.0 A typ. |
Single-phase/ two-phase 230 VAC input | 9.5 A typ. | 10 A typ. |
Power factor *1 | 0.9 min. |
Leakage current *3 | Three-phase 200 VAC input | 3.5 mA max. | 3.5 mA max. |
Three-phase 230 VAC input | 3.5 mA max. | 3.5 mA max. |
Inrush current *4 (for a cold start at 25°C) | Three-phase 200 VAC input | 18 A typ. | 22 A typ. |
Three-phase 230 VAC input | 16 A typ. | 16 A typ. |
Output character- istics | Rated output current | 85 A | 45 A |
Power Boost Function | 127.5 A | 67.5 A |
Voltage adjustment range *5 | 24 to 28 V (with V.ADJ) | 48 to 56 V (with V.ADJ) |
Ripple noise voltage *6 | Three-phase 200 to 240 VAC input | 170 mVp-p max. at 20 MHz of bandwidth | 190 mVp-p max. at 20 MHz of bandwidth |
Input variation influence *7 | 0.5% max. |
Load variation influence *8 | 1.5% max. |
Temperature variation influence | 200 to 240 VAC input | 0.05%/°C max. |
Startup time *9 | Three-phase 200 VAC input | 1,000 ms max. |
Three-phase 230 VAC input | 1,000 ms max. |
Output hold time *9 | Three-phase 200 VAC input | 25 ms typ. | 25 ms typ. |
Three-phase 230 VAC input | 25 ms typ. | 25 ms typ. |
Additional functions | Overload protection | Yes, inverted L voltage drop, automatic reset, power cut off if higher of rated output current continues and turn on the input again. Refer to the Overload Protection below. |
Overload protection for terminals | Yes, inverted L voltage drop, automatic reset, power cut off if overprotection (terminal blocks) continues and turn on the input again. Refer to the Overload Protection below. | No |
Overvoltage protection | Yes, 130% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again), Refer to Overvoltage Protection below. |
Series operation | Yes (For up to two Power Supplies; external diodes required.) |
Parallel operation | Yes (For up to two Power Supplies), Refer to Parallel Operation on Data sheet. Use with the switch for parallel operation set to the “PARALLEL” side (the rated output current limited to 80%). |
INPUT OK Indicator | Yes (LED: Green) |
DC OK Indicator | Yes (LED: Green) |
Iout > 100% Indicator | Yes (LED: Yellow) |
DC OK Signal Output | Yes (MOS FET relay output 30 VDC max., 50 mA max.) |
Iout > 100% signal output | Yes (MOS FET relay output 30 VDC max., 50 mA max.) |
Insulation | Withstand voltage | 3.0 kVAC for 1 min. (between all input terminals and all output terminals, signal output terminals), cutoff current 20 mA |
2.0 kVAC for 1 min. (between all input terminals and PE terminals), cutoff current 20 mA |
1.0 kVAC for 1 min. (between all output terminals, signal output terminals and PE terminals), cutoff current 25 mA (240 W/480 W/960 W) 1.0 kVAC for 1 min. (between all output terminals, signal output terminals and PE terminals), cutoff current 40 mA (2000 W) |
0.5 kVAC for 1 min. (between all output terminals and all signal output terminals), cutoff current 10 mA |
Insulation resistance | 100 MΩ min. (between all output terminals, signal output terminals and all input terminals / PE terminals) at 500 VDC |
Environ- ment | Ambient operating temperature *10 | -40 to 70°C (Derating is required according to the temperature. Refer to Engineering Data on Data sheet.) (with no condensation or icing) |
Storage temperature | -40 to 85°C (with no condensation or icing) |
Ambient operating humidity | 95% max. (Storage humidity: 95% max.) |
Vibration resistance *11 | 10 to 55 Hz, maximum 5 G, 0.42 mm single amplitude for 2 h each in X, Y, and Z directions |
Shock resistance *11 | 147 m/s2, 3 times each in ±X, ±Y, ±Z directions |
Reliability | MTBF *12 | 90,000 hrs |
Expected life *13 | 10 years min. |
Construc- tion | Weight | 3200 g max. |
Cooling fan | No |
Degree of protection | IP20 by EN/IEC 60529 |
Standards | Harmonic current emissions | Conforms to EN 61000-3-2 (single-phase, two-phase) *14 Complies with JIS C 61000-3-2 (single-phase, two-phase, three-phase) *15 |
EMI | Conducted emissions | Conforms to EN 61204-3 Class B, EN 55011 Class B (single-phase, two-phase, three-phase) |
Radiated emissions |
EMS | Conforms to EN 61204-3 high severity levels |
Safety standards | • UL 508 (Listing) • CSA C22.2 No.107.1 (cUL) • UL 62368-1 (Recognition) OVC II (≤ 3000 m) Pol2 • CSA C22.2 No.62368-1 (cUR) OVC II (≤ 3000 m) Pol2 • EN/IEC 62477-1 OVC III (≤ 2000 m) OVC II (2000 m < and ≤ 3000 m) Pol2 • EN/IEC 62368-1 OVC II (≤ 3000 m) Pol2 • RCM (EN61000-6-4) • Complies with PELV (EN/IEC 60204-1) • Complies with EN/IEC 61204-7 |
SEMI | Complies with SEMI F47-0706 (three-phase / single-phase / t |