OMRON S8VK-WB Switch Mode Power Supply (240/480/960-W)

Brand: OMRONModel: S8VK-WBProduct Name: Switch Mode Power Supply (240/480/960-W)Specification: Power rating240W480W960WOutput voltage24V24V24VEfficiency *1Three-phase 400 VAC input93% typ.94% typ.95%

  • model: S8VK-WB

Brand: OMRON

Model: S8VK-WB

Product Name: Switch Mode Power Supply (240/480/960-W)


Specification:

Power rating

240W

480W

960W

Output voltage

24V

24V

24V

Efficiency *1

Three-phase 400 VAC input

93% typ.

94% typ.

95% typ.

Two-phase 400 VAC input

93% typ.

94% typ.

95% typ.

Input
conditions

Input voltage range *2

Three-phase/two-phase 320 to 576 VAC, 450 to 810
VDC

Frequency *2

50/60 Hz (47 to 63 Hz)

Input current *1

Three-phase 400 VAC input

0.41 A typ.

0.79 A typ.

1.6 A typ.

Two-phase 400 VAC input

0.75 A typ.

1.5 A typ.

3.0 A typ.

Power factor *1

Three-phase 400 VAC input

0.9 min.

Leakage current
*3

Three-phase 400 VAC input

3.5 mA max.

Inrush current *4

Three-phase 400 VAC input

1.9 A typ.

3.3 A typ.

10.6 A typ.

Output
character-
istics

Rated output current

10 A

20 A

40 A

Power Boost Function

15 A

30 A

60 A

Voltage adjustment range *5

24 to 29.5 V (with V.ADJ)

24 to 28 V
(with V.ADJ)

Ripple noise
voltage *6

Three-phase
380 to 480 VAC input

100 mV p-p max.
at 20 MHz of
bandwidth

80 mV p-p max.
at 20 MHz of
bandwidth

50 mV p-p max.
at 20 MHz of
bandwidth

Input variation influence *7

0.5% max.

Load variation influence *8

1.5% max.

Temperature
variation influence

200 to 240 VAC input

0.05%/°C max.

Startup time *9

Three-phase 400 VAC input

1,000 ms max.

Output hold time
*9

Three-phase 400 VAC input

30 ms typ.

25 ms typ.

20 ms typ.

Additional
functions

Overload protection

Yes, automatic reset, intermittent operation type Refer
to Overload Protection on below.

Overvoltage protection

Yes, 130% or higher of rated output voltage, power
shut off (shut off the input voltage and turn on the input
again), Refer to Overvoltage Protection on below.

Series operation

Yes (For up to two Power Supplies; external diodes
required.)

Parallel operation

Yes (For up to two Power Supplies), Refer to Parallel
Operation on Data Sheet.

INPUT OK Indicator

Yes (LED: Green)

DC OK Indicator

Yes (LED: Green)

Iout > 100% Indicator

Yes (LED: Yellow)

DC OK Signal Output

Yes (MOS FET relay output 30 VDC max., 50 mA max.)

Iout > 100% signal output

Yes (MOS FET relay output 30 VDC max., 50 mA max.)

Insulation

Withstand voltage

3.0 kVAC for 1 min. (between all input terminals and
all output terminals, signal output terminals), cutoff
current 20 mA

2.5 kVAC for 1 min. (between all input terminals and
PE terminals), cutoff current 30 mA

1.0 kVAC for 1 min. (between all output terminals,
signal output terminals and PE terminals), cutoff
current 25 mA

0.5 kVAC for 1 min. (between all output terminals and
all signal output terminals), cutoff current 10 mA

Insulation resistance

100 MΩ min. (between all output terminals, signal
output terminals and all input terminals / PE
terminals) at 500 VDC

Environ-
ment

Ambient operating temperature *10

-40 to 70°C (Derating is required according to the
temperature. Refer to Engineering Data on Data
Sheet.) (with no condensation or icing)

Storage temperature

-40 to 85°C (with no condensation or icing)

Ambient operating humidity

95% max. (Storage humidity: 95% max.)

Vibration resistance *11

10 to 55 Hz, maximum 5 G, 0.42 mm single amplitude
for 2 h each in X, Y, and Z directions

Shock resistance *11

294 m/s2, 3 times each in ±X, ±Y, ±Z directions

Reliability

MTBF *12

170,000 hrs typ.

160,000 hrs typ.

140,000 hrs typ.

Expected life *13

10 years min.

Construc-
tion

Weight

890 g max.

1,200 g max.

1,800 g max.

Cooling fan

No

Degree of protection

IP20 by EN/IEC 60529

Power rating

240W

480W

960W

Output voltage

48V

48V

48V

Efficiency *1

Three-phase 400 VAC input

93% typ.

94% typ.

96% typ.

Two-phase 400 VAC input

93% typ.

94% typ.

95% typ.

Input
conditions

Input voltage range *2

Three-phase/two-phase 320 to 576 VAC, 450 to 810
VDC

Frequency *2

50/60 Hz (47 to 63 Hz)

Input current *1

Three-phase 400 VAC input

0.41 A typ.

0.78 A typ.

1.6 A typ.

Two-phase 400 VAC input

0.75 A typ.

1.5 A typ.

2.9 A typ.

Power factor *1

Three-phase 400 VAC input

0.9 min.

Leakage current
*3

Three-phase 400 VAC input

3.5 mA max.

Inrush current *4

Three-phase 400 VAC input

1.7 A typ.

3.0 A typ.

10.5 A typ.

Output
character-
istics

Rated output current

5 A

10 A

20 A

Power Boost Function

7.5 A

15 A

30 A

Voltage adjustment range *5

48 to 56 V (with V.ADJ)

Ripple noise
voltage *6

Three-phase
380 to 480 VAC input

50 m V p-p max.
at 20 MHz of
bandwidth

60 mV p-p max.
at 20 MHz of
bandwidth

60 mV p-p max.
at 20 MHz of
bandwidth

Input variation influence *7

0.5% max.

Load variation influence *8

1.5% max.

Temperature
variation influence

380 to 480 VAC input

0.05%/°C max.

Startup time *9

Three-phase 400 VAC input

1,000 ms max.

Output hold time
*9

Three-phase 400 VAC input

30 ms typ.

25 ms typ.

20 ms typ.

Additional
functions

Overload protection

Yes, automatic reset, intermittent operation type Refer
to Overload Protection on below.

Overvoltage protection

Yes, 130% or higher of rated output voltage, power
shut off (shut off the input voltage and turn on the
input again), Refer to Overvoltage Protection on below.

Series operation

Yes (For up to two Power Supplies; external diodes
required.)

Parallel operation

Yes (For up to two Power Supplies), Refer to Parallel
Operation on Data Sheet.

INPUT OK Indicator

Yes (LED: Green)

DC OK Indicator

Yes (LED: Green)

Iout > 100% Indicator

Yes (LED: Yellow)

DC OK Signal Output

Yes (MOS FET relay output 30 VDC max., 50 mA max.)

Iout > 100% signal output

Yes (MOS FET relay output 30 VDC max., 50 mA max.)

Insulation

Withstand voltage

3.0 kVAC for 1 min. (between all input terminals and
all output terminals, signal output terminals), cutoff
current 20 mA

2.5 kVAC for 1 min. (between all input terminals and
PE terminals), cutoff current 20 mA

1.0 kVAC for 1 min. (between all output terminals,
signal output terminals and PE terminals), cutoff
current 30 mA

0.5 kVAC for 1 min. (between all output terminals and
all signal output terminals), cutoff current 10 mA

Insulation resistance

100 MΩ min. (between all output terminals, signal
output terminals and all input terminals / PE
terminals) at 500 VDC

Environ-
ment

Ambient operating temperature *10

-40 to 70°C (Derating is required according to the
temperature. Refer to Engineering Data on Data
Sheet.) (with no condensation or icing)

Storage temperature

-40 to 85°C (with no condensation or icing)

Ambient operating humidity

95% max. (Storage humidity: 95% max.)

Vibration resistance *11

10 to 55 Hz, maximum 5 G, 0.42 mm single amplitude
for 2 h each in X, Y, and Z directions

Shock resistance *11

294 m/s2, 3 times each in ±X, ±Y, ±Z directions

Reliability

MTBF *12

170,000 hrs typ.

160,000 hrs typ.

140,000 hrs typ.

Expected life *13

10 years min.

Construc-
tion

Weight

890 g max.

1,200 g max.

1,800 g max.

Cooling fan

No

Degree of protection

IP20 by EN/IEC 60529


Power rating

240 W

480 W

960 W

Output voltage (VDC)

24 V/48 V

24 V/48 V

24 V/48 V

Standards
*15

Harmonic current emissions

Conforms to EN 61000-3-2 (three-phase/two-phase) *14

EMI

Conducted emissions

Conforms to EN 61204-3 Class B,
EN 55011 Class B (three-phase)
Conforms to EN 61204-3 Class A,
EN 55011 Class A (two-phase)

Radiated emissions

EMS

Conforms to EN 61204-3 high severity levels

Safety standards

UL 508 Listing
UL 62368-1 (Recognition) OVC II (≤ 3000 m) Pol2
CSA C22.2 No.62368-1 OVC II (≤ 3000 m) Pol2
EN/IEC 62477-1 OVC III (≤ 2000 m)
OVC II (2000 m < and ≤ 3000 m) Pol2
EN/IEC 62368-1 OVC II (≤ 3000 m) Pol2
RCM (EN61000-6-4)
Complies with PELV (EN/IEC 60204-1)
Complies with EN/IEC 61558-2-16
BIS (IS13252 (Part1): 2010)

SEMI

Complies with SEMI F47-0706 (three-phase 380 to 480 VAC input)