KYOWA

KYOWA EDB-41B Battery Unit for Instantaneous Power Failure

KYOWAEDB-41BBattery Unit for Instantaneous Power FailureSpecifications:Applicable EDXEDX-100A-1(H), EDX-100A-2(H), EDX-100A-4(H), EDX-200A-2H, EDX-200A-4HBuilt-in BatteriesBattery type: Nickel-Metal H

  • model:

KYOWA

EDB-41B

Battery Unit for Instantaneous Power Failure



Specifications:

Applicable EDX

EDX-100A-1(H), EDX-100A-2(H), EDX-100A-4(H), EDX-200A-2H, EDX-200A-4H

Built-in Batteries

Battery type: Nickel-Metal Hydride (Ni-MH) battery
Nominal capacity: 730 mAh, nominal voltage: 12 V

External Power Supply Input

11 V to 18 VDC
[DC IN] connector type: RM12BRD-4PH (HIROSE made)
DC power supply, AC adapter (Optional) for EDX-100A, or AC
adapter (Optional) for EDX-200A is used

Power Supply Output

External power voltage when using external power drive
Approx. 11 to 15 V when using this units drive (In instantaneous stop)
[DC OUT] terminal model: RM12BRD-4S (Hirose)
When operated on external power supply:
Voltage of the external power supply
When operated on the EDB-41B (During instantaneous power failure):
Approximately 11 to 15 V
[DC OUT] connector type: RM12BRD-4S (HIROSE made)

Charging Method

Automatically starts charging the battery by connecting the
external power supply. (Battery charging period: Max. 3.5 hours)
Starts discharging by pressing the [REFRESH] button.
(Refresh period: Max. 6.5 hours)

Indicator

[BATTERY LEVEL] LED (With [CHECK] button turned ON.)
Remaining capacity of the built-in battery is 10% or more:
Lights up green
Remaining capacity of the built-in battery is 10% or less:
Lights up red
[CHARGE] LED
During charging----------ON green
During discharging------ON orange
Charging complete------OFF

Buzzer

During instantaneous power supply, alarm buzzer is issued.

Operating Temperature

0 to 50°C (However, when charging and refreshing: 0 to 30°C)

Operating Humidity

20 to 90% (Non-condensing)

Storage Temperature

-20 to 50°C

Vibration Resistance

±29.42 m/s2 (3 G), 5 to 55 Hz (When operated)
±49.03 m/s2 (5 G), 5 to 55 Hz (When not operated)

Impact Resistance

196.10 m/s2 (20 G), 11 ms.

Dimensions

25 W x 132.5 H x 255 D mm (Excluding protrusions)

Weight

Approx. 500 g

Backup Time (Reference value)

Approx. 30 minutes
When 1 CDV-40B card (8 CHs) is installed to the
EDX-100A-1(H) and full loaded
Approx. 15 minutes
When 2 CDV-40B cards (16 CHs) are installed to the
EDX-100A-2(H) and full loaded
Approx. 5 minutes
When 4 CDV-40B cards (32 CHs) are installed to the
EDX-100A-4(H) and full loaded
Approx. 15 minutes
When 2 CDV-40B cards (16 CHs) are installed to the
EDX-200A-2H and full loaded
Approx. 5 minutes
When 4 CDV-40B cards (32 CHs) are installed to the
EDX-200A-4H and full loaded
* When built-in battery is fully charged and ambient
temperature is 20 to 30°C