KYOWA
DPM-42B-I Dynamic Strain Amplifier Card, Low Inverter Noise Type
Conditioner Cards
Specifications:
Measuring Targets | Strain gages Strain-gage transducers |
Channels | 4 |
Frequency Response | DC to 5 kHz (Deviation: Within ±10%) |
Compatible Bridge Resistance | 120 to 1000 Ω |
Gage Factor | 2.00 fixed |
Bridge Excitation | 2, 0.5 Vrms selectable 12 kHz sine wave |
Balance Adjustment Range |
|
Resistance | Within ±2.4% (±12000 ×10-6 strain) |
Capacity | Within 2000 pF |
Balance Adjustment Methods |
|
Resistance | Auto balance |
Capacity | CST method (Capacitance self-tracking) |
Measuring Range | [With bridge excitation 2 Vrms] 200, 500, 1k, 2k, 5k, 10k, 20k ×10-6 strain and OFF – 8 steps
[With bridge excitation 0.5 Vrms] 1k, 2k, 5k, 10k, 20k, 50k ×10-6 strain and OFF – 7 steps
Accuracy: Within ±0.5% |
Calibration Values (CAL) | Output at ±100% and ±50% of each range |
Nonlinearity | Within ±0.2% FS |
SN Ratio | 44 dBp-p or more (Range: 500 ×10-6 strain) |
LPF | Transfer characteristic : 2nd order Butterworth Cutoff frequencies : 10, 30, 100, 300, 1 kHz and FLAT (6 steps) Amplitude ratio at cutoff point : -3 ±1 dB Attenuation : -12 ±1 dB/oct. |
Resolution | 16 bits |
Additional Functions | Input check function, TEDS |
Monitor Output | Accuracy: ±5 V ±0.5% (At ±FS) Nonlinearity: Within ±0.5% FS |
Withstand Voltage | Between input and output: 250 VAC, 1 min. |
Noise Resistant | Low inverter noise |
Compliance | Directive 2014/30/EU (EMC) Directive 2011/65/EU, (EU) 2015/863 (10 restricted substances) (RoHS) |
|