Power rating | 15 W | 30 W |
Output voltage (VDC) | 5 V | 12 V | 24 V | 5 V | 12 V | 24 V |
Efficiency | 230 VAC input *6 | 77% typ. | 77% typ. | 80% typ. | 79% typ. | 82% typ. | 86% typ. |
Input | Voltage range *1 | Single-phase, 85 to 264 VAC, 90 to 350 VDC *10 |
Frequency *1 | 50/60 Hz (47 to 450 Hz) |
Current | 115 VAC input *6 | 0.32 A typ. | 0.3 A typ. | 0.31 A typ. | 0.5 A typ. | 0.57 A typ. | 0.58 A typ. |
230 VAC input *6 | 0.2 A typ. | 0.21 A typ. | 0.2 A typ. | 0.32 A typ. | 0.37 A typ. | 0.36 A typ. |
Power factor *6 | 230 VAC input, 100% load | 0.42 min. | 0.43 min. | 0.42 min. | 0.43 min. |
Leakage current | 115 VAC input | 0.14 mA typ. | 0.13 mA typ. |
230 VAC input | 0.25 mA typ. | 0.24 mA typ. |
Inrush current *2 (for a cold start at 25°C) | 115 VAC input | 16 A typ. | 16 A typ. |
230 VAC input | 32 A typ. | 32 A typ. |
Output | Rated output current | 3 A | 1.2 A | 0.65 A | 5 A | 2.5 A | 1.3 A |
Boost current | 3.6 A | 1.44 A | 0.78 A | 6 A | 3 A | 1.56 A |
Voltage adjustment range *3 | -10% to 15% (with V.ADJ) (guaranteed) |
Ripple & Noise voltage *4 | 100 to 240 VAC input, 100% load *6 | 60 mVp-p max. at 20 MHz of bandwidth | 50 mVp-p max.at 20 MHz of bandwidth | 30 mVp-p max. at 20 MHz of bandwidth | 30 mVp-p max. at 20 MHz of bandwidth | 30 mVp-p max. at 20 MHz of bandwidth | 30 mVp-p max. at 20 MHz of bandwidth |
Input variation influence *8 | 0.4% max. | 0.4% max. |
Load variation influence *7 | 0.8% max. | 0.8% max. |
Temperature variation influence | 115 to 230 VAC input | 0.05%/°C max. | 0.05%/°C max. |
Start up time *2 | 115 VAC input *6 | 530 ms typ. | 520 ms typ.. | 580 ms typ. | 550 ms typ. | 550 ms typ. | 600 ms typ. |
230 VAC input *6 | 330 ms typ. | 400 ms typ. | 400 ms typ. | 430 ms typ. | 490 ms typ. | 480 ms typ. |
Hold time *2 | 115 VAC input *6 | 28 ms typ. | 29 ms typ. | 32 ms typ. | 33 ms typ. | 36 ms typ. | 23 ms typ. |
230 VAC input *6 | 134 ms typ. | 138 ms typ. | 134 ms typ. | 177 ms typ. | 170 ms typ. | 154 ms typ. |
Additional functions | Overload protection | Yes, automatic reset | Yes, automatic reset |
Overvoltage protection *5 | Yes, 130% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) |
Series operation | Yes (For up to two Power Supplies, external diodes are required.) |
Parallel operation | Yes (Refer to Safety Precautions) (For up to two Power Supplies) |
Output indicator | Yes (LED: Green), lighting from 80% to 90% or more of rated voltage |
Insulation | Withstand voltage | 3.0 kVAC for 1 min. (between all input terminals and output terminals), current cutoff 20 mA |
2.0 kVAC for 1 min. (between all input terminals and PE terminals), current cutoff 20 mA |
1.0 kVAC for 1 min. (between all output terminals and PE terminals), current cutoff 20 mA |
Insulation resistance | 100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC |
Environ- ment | Ambient operating temperature *12 | -40 to 70°C (Derating is required according to the temperature. Refer to Engineering Data) (with no condensation or icing) |
Storage temperature | -40 to 85°C (with no condensation or icing) |
Ambient operating humidity | 0% to 95% (Storage humidity: 0% to 95%) |
Vibration resistance | 10 to 55 Hz, 0.375 mm half amplitude for 2 h each in X, Y, and Z directions |
Shock resistance | 150 m/s2, 3 times each in ±X, ±Y, and ±Z directions |
Reliability | MTBF | 135,000 hrs min. |
Life expectancy *9 | 10 years min. |
Con- struction | Weight | 150 g max. | 195 g max. |
Cooling fan | No |
Degree of protection | IP20 by EN/IEC 60529 |
Standards | Harmonic current emissions | Conforms to EN 61000-3-2 |
EMI | Conducted Emissions | Conforms to EN 61204-3 Class B, EN 55011 Class B |
Radiated Emissions | Conforms to EN 61204-3 Class B, EN 55011 Class B |
EMS | Conforms to EN 61204-3 high severity levels |
Approved Standards | UL Listed: UL 508 (Listing, Class2 Output: Per UL 1310) UL UR: UL 62368-1 (Recognition) cUL: CSA C22.2 No.107.1 (Class2 Output: Per CSA C22.2 No.223) cUR:CSA C22.2 No.62368-1 EN: EN 62477-1, EN 62368-1 |
Conformed Standards | PELV (EN 60204-1, EN 62477-1) |
EN 61558-2-16 |
RCM (EN61000-6-4) |
Marine Standards | Lloyd’s register *10 *11 |
SEMI | Conforms to F47-0706 ( 200 to 240 VAC input) |