Power rating | 120 W | 240 W |
Output voltage | 24 V | 24 V |
Efficiency *1 | 3-phase, 400 VAC input | 89% typ. | 89% typ. |
Input | Voltage range *2 | 3-phase, 380 to 480 VAC (allowable range: 320 to 576 VAC) 2-phase, 380 to 480 VAC (allowable range: 340 to 576 VAC) 450 to 600 VDC (allowable range: 450 to 810 VDC) |
Frequency *2 | 50/60 Hz (47 to 63 Hz) |
Input Current *1 | 3-phase, 400 VAC input | 0.40 A typ. | 0.74 A typ. |
Power factor *6 | 3-phase, 400 VAC input | - | - |
Leakage current *3 | 3-phase, 400 VAC input | 3.5 mA max./0.70 mA typ. | 3.5 mA max./0.80 mA typ. |
Inrush current (for a cold start at 25°C) *4 | 3-phase, 400 VAC input | 28 A typ. | 29 A typ. |
Output | Rated output current | 5 A | 10 A |
Boost current | 6 A | 12 A |
Voltage adjustment range *5 | 24 to 29.5 VDC (with V.ADJ) (guaranteed) |
Ripple & Noise voltage *6 | 3-phase, 400 VAC input | 40 mV p-p max. at 20 MHz of bandwidth | 50 mV p-p max. at 20 MHz of bandwidth |
Input variation influence *7 | 0.5% max. |
Load variation influence *8 | 1.5% max. |
Temperature variation influence | 3-phase, 400 VAC input | 0.05%/°C max. |
Start up time *9 | 3-phase, 400 VAC input | 600 ms typ. | 600 ms typ. |
Hold time *9 | 3-phase, 400 VAC input | 35 ms typ. | 25 ms typ. |
Additional functions | Overload protection | Yes, automatic reset, intermittent operation type, Refer to Overload Protection on Catalog for details. |
Overvoltage protection | Yes, 130% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again), Refer to Overvoltage Protection on Catalog for details. |
Series operation | Yes (For up to two Power Supplies, external diodes are required.) |
Parallel operation | Yes (For up to two Power Supplies), Refer to Parallel Operation on Catalog for details. |
Output indicator | Yes (LED: Green), lighting from 80% to 90% or more of rated voltage |
Insulation | Withstand voltage | 3.0 kVAC for 1 min. (between all input terminals and output terminals) cutoff current 20 mA 2.5 kVAC for 1 min. (between all input terminals and PE terminal) cutoff current 20 mA 1.0 kVAC for 1 min. (between all output terminals and PE terminal) cutoff current 30 mA |
Insulation resistance | 100 MΩ min. (between all output terminals and all input terminals / PE terminal) at 500 VDC |
Envi- ronment | Ambient operating temperature *10 | -40 to 70°C (However, only startup is guaranteed for between -40°C to -25°C. (3-phase only)) (Derating is required according to the temperature.) (with no condensation or icing) |
Storage temperature | -40 to 85°C (with no condensation or icing) |
Ambient operating humidity | 0% to 95% (Storage humidity: 0% to 95%) |
Vibration resistance *11 | 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z directions |
Shock resistance *11 | 150 m/s2, 3 times each in ±X, ±Y, and ±Z directions |
Reliability | MTBF *12 | 135,000 hrs min. |
Life expectancy *13 | 10 years min. |
Con- struction | Weight | 650 g max. | 850 g max. |
Cooling fan | No |
Degree of protection | IP20 by EN / IEC 60529 |
Standards | Harmonic current emissions | Conforms to EN 61000-3-2 (3-phase, 2-phase) |
EMI | Conducted Emission | Conforms to EN 61204-3 Class B, EN 55011 Class B (3-phase, 2-phase) |
Radiated Emission |
EMS | EN 61204-3 high severity levels |
Safety standards | UL 508 (Listing) UL 61010-2-201 (Listing) OVCIII/OVCII Pol2 *16 CSA C22.2 No.61010-2-201 (cUL) OVCIII/OVCII Pol2 *16 EN/IEC 61010-2-201 OVCIII/OVCII Pol2 *16 EN/IEC 62477-1 OVCIII Pol2 *15 RCM (EN61000-6-4) Lloyd’s standards *17 Conforms to SELV(EN/IEC 61558-2-16) Conforms to PELV (EN/IEC 60204-1) Conforms to EN/IEC 61558-2-16 *15 BIS (IS 13252 (Part1)) |
SEMI | Conforms to F47-0706 (3-phase, 380 to 480 VAC input) |
Power rating | 480 W | 960 W |
Output voltage | 24 V | 24 V |
Efficiency *1 | 3-phase, 400 VAC input | 93% typ. | 93% typ. |
Input | Voltage range *2 | 3-phase, 380 to 480 VAC (allowable range: 320 to 576 VAC) 2-phase, 380 to 480 VAC (allowable range: 340 to 576 VAC) 450 to 600 VDC (allowable range: 450 to 810 VDC) | 3-phase, 380 to 480 VAC (allowable range: 320 to 576 VAC) 2-phase, 380 to 480 VAC (allowable range: 340 to 576 VAC) |
Frequency *2 | 50/60 Hz (47 to 63 Hz) |
Input Current *1 | 3-phase, 400 VAC input | 0.80 A typ. | 1.6 A typ. |
Power factor *6 | 3-phase, 400 VAC input | 0.9 min. |
Leakage current *3 | 3-phase, 400 VAC input | 3.5 mA max./1.0 mA typ. | 3.5 mA max./1.2 mA typ. |
Inrush current (for a cold start at 25°C) *4 | 3-phase, 400 VAC input | 4 A typ. | 6 A typ. |
Output | Rated output current | 20 A | 40 A |
Boost current | 24 A | 48 A |
Voltage adjustment range *5 | 24 to 29.5 VDC (with V.ADJ) (guaranteed) |
Ripple & Noise voltage *6 | 3-phase, 400 VAC input | 30 mV p-p max. at 20 MHz of bandwidth | 60 mV p-p max. at 20 MHz of bandwidth |
Input variation influence *7 | 0.5% max. |
Load variation influence *8 | 1.5% max. |
Temperature variation influence | 3-phase, 400 VAC input | 0.05%/°C max. |
Start up time *9 | 3-phase, 400 VAC input | 500 ms typ. | 500 ms typ. |
Hold time *9 | 3-phase, 400 VAC input | 40 ms typ. | 35 ms typ. |
Additional functions | Overload protection | Yes, automatic reset, intermittent operation type, Refer to Overload Protection on Catalog for details. |
Overvoltage protection | Yes, 130% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again), Refer to Overvoltage Protection on Catalog for details. |
Series operation | Yes (For up to two Power Supplies, external diodes are required.) |
Parallel operation | Yes (For up to two Power Supplies), Refer to Parallel Operation on Catalog for details. For 960 W, set the operation switch to the "PARALLEL" side (limit the rated output current to 80%). |
Output indicator | Yes (LED: Green), lighting from 80% to 90% or more of rated voltage |
Insulation | Withstand voltage | 3.0 kVAC for 1 min. (between all input terminals and output terminals) cutoff current 20 mA 2.5 kVAC for 1 min. (between all input terminals and PE terminal) cutoff current 20 mA 1.0 kVAC for 1 min. (between all output terminals and PE terminal) cutoff current 30 mA |
Insulation resistance | 100 MΩ min. (between all output terminals and all input terminals / PE terminal) at 500 VDC |
Envi- ronment | Ambient operating temperature *10 | -40 to 70°C (However, only startup is guaranteed for between -40°C to -25°C. (3-phase only)) (Derating is required according to the temperature.) (with no condensation or icing) |
Storage temperature | -40 to 85°C (with no condensation or icing) |
Ambient operating humidity | 0% to 95% (Storage humidity: 0% to 95%) |
Vibration resistance *11 | 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z directions |
Shock resistance *11 | 150 m/s2, 3 times each in ±X, ±Y, and ±Z directions |
Reliability | MTBF *12 | 135,000 hrs min. |
Life expectancy *13 | 10 years min. |
Con- struction | Weight | 1,400 g max. | 2,000 g max. |
Cooling fan | No |
Degree of protection | IP20 by EN / IEC 60529 |
Standards | Harmonic current emissions | Conforms to EN 61000-3-2 (3-phase, 2-phase) | Conforms to EN61000-3-2 (3-phase, 2-phase) *14 |
EMI | Conducted Emission | Conforms to EN 61204-3 Class B, EN 55011 Class B (3-phase, 2-phase) | Conforms to EN 61204-3 Class B, EN 55011 Class B (3-phase: 100% or less of rated output current) (2-phase: 45% or less of rated output current) Conforms to EN 61204-3 Class A, EN 55011 Class A (2-phase:45 to 100% of rated output current) |
Radiated Emission |
EMS | EN 61204-3 high severity levels |
Safety standards (*14) | UL 508 (Listing) UL 61010-2-201 (Listing) OVCIII/OVCII Pol2 *16 CSA C22.2 No.61010-2-201 (cUL) OVCIII/OVCII Pol2 *16 EN/IEC 61010-2-201 OVCIII/OVCII Pol2 *16 EN/IEC 62477-1 OVCIII Pol2 *15 RCM (EN61000-6-4) Lloyd’s standards *17 Conforms to SELV (EN/IEC 61558-2-16) Conforms to PELV (EN/IEC 60204-1) Conforms to EN/IEC 61558-2-16 *15 BIS (IS 13252 (Part1)) |
SEMI | Conforms to F47-0706 (3-phase, 380 to 480 VAC input) |