KEYENCE
IV3-G600CA
Compact model sensor head Wide field of view sensor model Colour AF type
Specifications:
Model | IV3-G600CA |
Type | Wide view |
Installed distance | 50 mm or more *1 |
Field of view | Installed distance 50 mm: 51 (H) × 38 (V) mm Installed distance 3000 mm: 2730 (H) × 2044 (V) mm (typical example) |
Image receiving element | Type | 1/2.9 inch colour CMOS |
Number of pixels | 1280 (H) × 960 (V) |
Focus adjustment | Auto *2 |
Exposure time | 12 μs to 9 ms |
Lights | Illumination | White LED |
Lighting method | Pulse /continuous lighting is switchable. |
Indicators | 2 (the same display details for both indicators) |
Environmental resistance | Enclosure rating | IP67 *3 |
Ambient temperature | 0 to +50°C (No freezing) *4 |
Relative humidity | 35 to 85% RH (No condensation) |
Vibration resistance | 10 to 55 Hz; double amplitude 1.5 mm; 2 hours in each of the X, Y, and Z directions *5 |
Shock resistance | 500 m/s2, 3 times in each of the 6 directions *5 |
Material | Main unit case: Zinc die-casting, Front cover: Acrylic, Operation indicator cover: TPU |
Weight | Approx. 75 g (without the AI Lighting unit) Approx. 225 g (with the AI Lighting unit) |
*1 Removing the polarising filter is recommended when used at distances of 3 m or more. *2 The focus position can be automatically adjusted at the time of installation. This function is deactivated during operation. A different focus position can be registered for each program. *3 Except when the polarising filter (OP-88642/OP-88643/OP-88646/OP-88647) is mounted. *4 For situations where the operating ambient temperature will exceed 40°C, follow KEYENCE’s specified heat dissipation measures to ensure the case temperature does not exceed the rated maximum temperature (65°C). Check the instruction manual for more information. *5 Except when the dome attachment (IV2-GD05/IV2-GD10) is mounted. |