Power ratings | 15 W | 30 W |
Output voltage (VDC) | 5 V | 12 V | 24 V | 5 V | 12 V | 24 V |
Efficiency | With 100-VAC input | 74% typical | 79% typical | 83% typical | 74% typical | 81% typical | 85% typical |
With 200-VAC input | 73% typical | 78% typical | 80% typical | 74% typical | 80% typical | 86% typical |
Input | Voltage *1 | 100 to 240 VAC (allowable range: 85 to 264 VAC, 80 to 370 VDC *5) |
Frequency *1 | 50/60 Hz (47 to 450 Hz) |
Current | With 100-VAC input | 0.45 A max., 0.34 A typical | 0.9 A max., 0.66 A typical |
With 200-VAC input | 0.25 A max., 0.22 A typical | 0.6 A max., 0.4 A typical |
Power factor *6 | --- |
Harmonic current regulation | Conforms to EN61000-3-2 |
Leakage current | With 100-VAC input | 0.5 mA max. |
With 200-VAC input | 1.0 mA max. |
Inrush current *2 | With 100-VAC input | 17.5 A max., 14 A typical |
With 200-VAC input | 35 A max., 28 A typical |
Output | Voltage adjustment range *3 | - 10% to 15% (with V.ADJ) |
Ripple noise voltage (at rated I/O) | 60 mV max. | 70 mV max. | 60 mV max. | 60 mV max. | 90 mV max. | 150 mV max. |
Input variation influence | 0.5% max. (at 85- to 264-VAC input, 100% load) |
Load variation influence (rated input voltage) | 2.0% max. (5 V), 1.5% max. (12 V, 24 V), (with rated input, 0 to 100% load) |
Temperature variation influence | 0.05%/°C max. |
Startup time (at rated I/O) *2 | With 100-VAC input | 580 ms typical | 530 ms typical | 600 ms typical | 500 ms typical | 560 ms typical | 560 ms typical |
With 200-VAC input | 340 ms typical | 360 ms typical | 400 ms typical | 360 ms typical | 380 ms typical | 400 ms typical |
Output hold time (at rated I/O) *2 | With 100-VAC input | 39 ms typical | 27 ms typical | 28 ms typical | 31 ms typical | 22 ms typical | 31 ms typical |
With 200-VAC input | 187 ms typical | 134 ms typical | 134 ms typical | 174 ms typical | 123 ms typical | 140 ms typical |
Additional functions | Overload protection *2 | The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC). |
Overvoltage protection *2 | Yes *4 |
Output voltage indication | No |
Output current indication | No |
Peak-hold current indication | No |
Maintenance forecast monitor indication | No |
Maintenance forecast monitor output | No |
Total run time monitor indication | No |
Total run time monitor output | No |
Undervoltage alarm indication | Yes (color: red) |
Undervoltage alarm output | No |
Parallel operation | No (However, backup operation is possible. An external diode is required.) |
Series operation | Models with 24-V output: Possible for up to 2 Power Supplies (with external diode) Models with 5- or 12-V output: Not possible |
Other | Operating ambient temperature | Refer to the derating curve in Engineering Data. (with no icing or condensation) |
Storage temperature | - 25 to 65°C |
Operating ambient humidity | 25% to 85% (Storage humidity: 25% to 90%) |
Dielectric strength | 3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA) 2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA) 1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 20 mA) |
Insulation resistance | 100 MΩ min. (between all outputs and all inputs/PE terminals) at 500 VDC |
Vibration resistance | 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions |
Shock resistance | 150 m/s2 , 3 times each in ±X, ±Y, and ±Z directions |
Output indicator | Yes (color: green) |
EMI | Conducted Emissions | Conforms to EN55011 Group1 Class B and based on FCC Class A |
Radiated Emissions | Conforms to EN55011 Group1 Class B |
EMS | Conforms to EN61204-3 high severity levels |
Approved standards | UL 508 (Listing, Class2 Output: Per 1310) UL 62368-1 CSA C22.2 No.107.1 (cUL) (Class2 Output: Per CSA C22.2 No.223) CSA C22.2 No.62368-1 (cUR) EN 62477-1, EN 62368-1 RCM mark |
SEMI | F47-0706 (With 200-VAC input) |
Weight | 160 g max. | 180 g max. |