Power rating | 15 W |
Output voltage (VDC) | 5 V | 12 V | 15 V | 24 V |
Efficiency *1 | 100 VAC input | 80% typ. | 84% typ. | 84% typ. | 85% typ. |
200 VAC input | 80% typ. | 84% typ. | 84% typ. | 86% typ. |
230 VAC input | 80% typ. | 84% typ. | 84% typ. | 86% typ. |
Input | Voltage range *1 | Single phase, 85 to 264 VAC, 80 to 370 VDC |
Frequency *1 | 50/60 Hz (47 to 450 Hz) |
Current *1 | 100 VAC input | 0.32 A typ. |
200 VAC input | 0.2 A typ. |
Power factor *1 | --- |
Leakage current *1 | 100 VAC input | 0.5 mA max. |
200 VAC input | 1 mA max. |
Inrush current *1 (for a cold start at 25°C) | 100 VAC input | 14 A typ. |
200 VAC input | 28 A typ. |
Output | Rated Output Current | 3 A | 1.3 A | 1 A | 0.65 A |
Voltage adjustment range *1 | -10% to 15% (with V.ADJ) |
Ripple & Noise voltage *1 | 100 to 240 VAC input | 40 mVp-p max. | 40 mVp-p max. | 40 mVp-p max. | 60 mVp-p max. |
Input variation influence *1 | 0.5% max. |
Load variation influence *1 | 1.0% max. |
Temperature variation influence | 100 to 240 VAC input | 0.05%/°C max. |
Startup time *1 | 100 VAC input | 1,000 ms max. |
200 VAC input | 1,000 ms max. |
Hold time *1 | 100 VAC input | 15 ms typ. | 14 ms typ. | 15 ms typ. | 15 ms typ. |
200 VAC input | 75 ms typ. | 70 ms typ. | 75 ms typ. | 70 ms typ. |
Additional functions | Overload protection | Yes, automatic reset |
Overvoltage protection *1 | Yes, 120% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) |
Overheat protection | No |
Series operation | Yes (For up to two Power Supplies, external diodes are required.) |
Parallel operation | No (However, backup operation is possible, external diodes are required.) |
Remote sensing | No |
Remote control | No |
Output indicator | Yes (LED: Green) |
Insulation | Withstand voltage | 3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA |
2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA |
1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA |
Insulation resistance | 100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC |
Environ- ment | Ambient operating temperature | -20 to 70°C (Derating is required according to the temperature.) (with no condensation or icing) |
Storage temperature | -25 to 75°C (with no condensation or icing) |
Ambient operating humidity | 90% max. (Storage humidity: 90% max.) |
Vibration resistance | 10 to 55 Hz, 4.5 G max., 0.375-mm half amplitude for 2 h each in X, Y, and Z directions |
Shock resistance | 150 m/s2, 3 times each in ±X, ±Y, ±Z directions |
Reliability | MTBF | 135,000 hrs min. |
Life expectancy *1 | 10 years min. |
Con- struction | Dimensions (W×H×D) | Refer to Dimensions. |
Weight | 250 g |
Cooling fan | No |
Degree of protection | --- |
Standards | Harmonic current emissions | Conforms to EN 61000-3-2 |
EMI *1 | Conducted Emissions | Conforms to EN 61204-3 Class B, EN 55011 Class B |
Radiated Emissions | Conforms to EN 61204-3 Class B, EN 55011 Class B |
EMS | Conforms to EN 61204-3 high severity levels |
Safety Standards *2 | UL 508 (Listing, excluding models with connector option) UL 62368-1 (Recognition, OVCII [≤ 3,000 m], Pol2) CSA C22.2 No.107.1 (excluding models with connector option) CSA C22.2 No.62368-1 (excluding models with connector option) EN 62477-1 (OVCIII [≤ 2,000 m], OVCII [> 2,000 m and ≤ 3,000 m], Pol2) EN/IEC 62368-1 (OVCII [≤ 3,000 m], Pol2) Conforms to EN/IEC 61558-2-16 Conforms to PELV (EN/IEC 60204-1) RCM (EN61000-6-4) |
Marine Standards | No |
SEMI | Conforms to F47-0706 (200 VAC input) |