Model | LK-G3001*1 |
Type | Separate monitor model*2 |
Head compatibility | All LK-G sensor heads are compatible |
Connectable number of heads | Maximum of 2 units |
Display | Minimum display unit | 0.01 µm |
Display range | ±9,999.99 mm to ±9,999.99 µm (Selectable from six levels) |
Display cycle | 10 times/sec. |
Terminal block | Analogue voltage output | ±10 V x 2 outputs, output impedance: 100 Ω |
Analogue current output | 4 to 20 mA x 2 outputs, maximum load resistance: 350 Ω |
Timing input | For OUT1, non-voltage input |
Reset input |
Auto-zero input |
Laser remote interlock input | Non-voltage input |
Comparator output | For OUT1, NPN open-collector output |
Alarm output | For OUT1, NPN open-collector output (N.C.) |
Expansion connector | Timing input | For OUT2, non-voltage input |
Reset input |
Auto-zero input |
Program switching input | Non-voltage input x 3 inputs |
Laser-Off input | For Head A/Head B, non-voltage input |
Comparator output | For OUT2, NPN open-collector output |
Alarm output | For OUT2, NPN open-collector output (N.C.) |
Binary | Binary output | Measured data output (21 bits), OUT1/OUT2 selectable, NPN open-collector output |
Strobe output | NPN open-collector output |
Binary selector output |
Binary selector input | Non-voltage input |
RS-232C interface | Measured data output and control input/output (Maximum baud rate: 115,200 bps, selectable) |
USB interface | In conformity with USB Revision 2.0 Full speed (USB1.1 compatible) |
Major functions | 2 OUT simultaneous measurement, Operation, Averaging, Filter, Calibration, Measurement, AUTO ZERO, Sampling frequency setting, Mutual interference prevention, Data storage, 8-program memory, ECO mode, ABLE setting, Target setting, ABLE tuning, Selection of measurement surface of transparent target, Statistics processing, Connection of setting support software, Selectable head-mounting, etc. |
Rating | Power voltage | 24 VDC ±10 %, Ripple (P-P) 10 % or less |
Current consumption | When connecting one measurement head 500 mA or less / When connecting two measurement heads 600 mA or less |
Environmental resistance | Ambient temperature | 0 to +50 °C |
Relative humidity | 35 to 85 % RH (No condensation) |
Weight | Approx. 370 g |
*1 The rating of the NPN open-collector: 50 mA max. (40 V max.), residual voltage of 1 V max. The rating of non-voltage input: 1 V or less ON voltage, 0.6 mA or less OFF current. *2 LK-G3001 can be operated singly. The measured value display and setting modifications can be performed on the display panel (LK-GD500) or via the setting support software (LK-H1W). |