Model | IB-1050 |
Type | DIN rail mount |
Main unit/Expansion unit | Expansion unit |
Head compatibility | Yes |
Display | Display resolution | 0.01 %, 0.1 %, 1 % (switchable) |
Display range | –99.999 to 99.999, –99.99 to 99.99 –99.9 to 99.9, –99 to 99 (switchable) |
Digital display method | Dual7-segmentdisplay Upper level: 5 red digits Lower level: 5 green digits |
Operation indicator | Judgment indicator: 2-color (green/red) LED (HI, GO, LO) Bank indicator: Green LED x 4 Laser emission warning indicator: Green LED Others: Green LED x 8, red LED x 3 |
Analogue output voltage | No |
Analogue current output |
Control Input | Bank switch input, zero shift input | Non-voltage input *1 |
Control input | Zero-shift input |
Laser emission stop input |
Timing input |
Reset input |
Adjust input |
Control output | Judgment output (check output) | Open collector (NPN/PNP switchable, N.O./N.C. switchable) *2 |
Power supply | Power consumption | 2400 mW or less (at 30 V, 80 mA max.) *3 *4 (including analog current output) |
Power voltage | Supplied from main unit *3 |
Environmental resistance | Pollution degree | 2 |
Ambient temperature | -10 to +50 °C (No freezing) |
Relative humidity | 35 to 85 % RH (No condensation) |
Vibration resistance | 10 to 55 Hz, compound amplitude 1.5 mm, 2 hours each for X, Y, Z axes |
Material | Main unit case/Front panel: polycarbonate, keytop: polyacetal, cable: PVC |
Weight | Approx. 140 g (including accessories) |
*1 The four external input wires are assigned with desired inputs. Rated no-voltage input: ON voltage 2 V or less, OFF current 0.05 mA or less Rated voltage input: Max. input rating 30 V or less, ON voltage 7.5 V or more, OFF current 0.05 mA or less *2 Rated NPN open collector output: Max. 100 mA/ch (20 mA/ch when expansion units are connected), 30 V or less, residual voltage 1 V or less Rated PNP open collector output: Max. 50 mA/ch (20 mA/ch when expansion units are connected), power voltage or less, residual voltage 2 V or less *3 Use with the over current protection device which is rated 30 V or more and not more than 1 A. *4 Does not include the power consumption of the load. The power consumption with expansion units installed is the total of each amplifier unit’s power consumption. Example: When using one main unit (IB-1000) with two expansion units (IB-1050) (2400 mW X 1) + (2400 mW X 2) = 7200 mW |