OMRON S8FS-C Switch Mode Power Supply (15/25/35/50/75/100/150/200/350-W)

Brand: OMRONModel: S8FS-CProduct Name: Switch Mode Power Supply (15/25/35/50/75/100/150/200/350-W)Specification: Power rating15 WOutput voltage (VDC)5 V12 V15 V24 VEfficiency *115 VAC input80% typ.84%

  • model: S8FS-C

Brand: OMRON

Model: S8FS-C

Product Name: Switch Mode Power Supply (15/25/35/50/75/100/150/200/350-W)


Specification:

Power rating

15 W

Output voltage (VDC)

5 V

12 V

15 V

24 V

Efficiency *

115 VAC input

80% typ.

84% typ.

84% typ.

85% typ.

230 VAC input

82% typ.

85% typ.

86% typ.

87% typ.

Input

Voltage range *

Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DC
input is the positive side and safety standards do not apply.) (Derating is
required according to the input voltage. Refer to Derating Curves on
Data Sheet.)

Frequency *

50 /60 Hz (47 to 450 Hz)

Current *

115 VAC input

0.3 A typ.

230 VAC input

0.19 A typ.

Power factor

--

Leakage
current

115 VAC input

0.05 mA

0.05 mA

0.05 mA

0.05 mA

230 VAC input

0.10 mA

0.10 mA

0.10 mA

0.10 mA

Inrush
current *
(for a cold
start at 25°)

115 VAC input

16 A typ.

230 VAC input

32 A typ.

Output

Rated Output Current

3 A

1.3 A

1 A

0.7 A

Voltage adjustment range *

-10% to 10% (with V. ADJ)

Ripple & Noise
voltage *

100 to 240
VAC input

30 mVp-p max.

30 mVp-p max.

40 mVp-p max.

30 mVp-p max.

Input variation influence *

0.5% max.

Load variation influence *

1.0% max.

Temperature
variation
influence

100 to 240
VAC input

0.03%/°C max.

Startup
time *

115 VAC input

490 ms typ.

500 ms typ.

470 ms typ.

480 ms typ.

230 VAC input

470 ms typ.

480 ms typ.

450 ms typ.

460 ms typ.

Hold time *

115 VAC input

14 ms typ.

16 ms typ.

18 ms typ.

15 ms typ.

230 VAC input

83 ms typ.

87 ms typ.

92 ms typ.

79 ms typ.

Addi-
tional
func-
tions

Overload protection

Yes, automatic reset

Overvoltage protection *

Yes, 115% or higher of rated output voltage, power shut off (shut off the
input voltage and turn on the input again)

Overheat protection

No

Series operation

Yes (For up to 2 Power Supplies, external diodes are required.)

Parallel operation

No (However, backup operation is possible, external diodes are required.)

Remote sensing

No

Remote control

No

Output indicator

Yes (LED: Green)

Insula-
tion

Withstand voltage

3 kVAC for 1 min. (between all input terminals and output terminals)
current cutoff 20 mA

2 kVAC for 1 min. (between all input terminals and PE terminals) current
cutoff 20 mA

1 kVAC for 1 min. (between all output terminals and PE terminals) current
cutoff 20 mA

Insulation resistance

100 MΩ min. (between all output terminals and all input terminals/PE
terminals) at 500 VDC

Envi-
ron-
ment

Ambient operating temperature

-20 to 60°C (Derating is required according to the temperature. Refer
to Derating Curves on Data Sheet.) (with no condensation or icing)

Storage temperature

-40 to 85°C (with no condensation or icing)

Ambient operating humidity

20% to 90% (Storage humidity: 10% to 95%)

Vibration resistance

10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z
directions
10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Z
directions

Shock resistance

150 m/s2, 3 times each in ±X, ±Y, ±Z directions

Relia-
bility

MTBF

135,000 hrs min.

Life expectancy *

10 years min.

Con-
struc-
tion

Dimensions (W × H × D)

Refer to Dimensions.

Weight

150 g max.

Cooling fan

No

Degree of protection

--

Stan-
dards

Harmonic current emissions

Conforms to EN 61000-3-2, GB17625.1

EMI

Conducted
Emissions

Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254

Radiated
Emissions

Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254

EMS

Conforms to EN 61204-3 high severity levels

Safety Standards

Approved Standards
UL: cURus UL 62368-1 (Recognition) OVC II Pol2
CSA: cURus C22.2 No62368-1
CCC: GB4943
Conformed Standards
EN: EN 62368-1 OVC II Pol2
RCM (EN61000-6-4)

Marine Standards

No

SEMI

No

* Refer to Conditions of below.

Power rating

25 W

Output voltage (VDC)

5 V

12 V

15 V

24 V

Efficiency *

115 VAC input

80% typ.

84% typ.

85% typ.

86% typ.

230 VAC input

82% typ.

86% typ.

88% typ.

88% typ.

Input

Voltage range *

Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DC
input is the positive side and safety standards do not apply.) (Derating is
required according to the input voltage. Refer to Derating Curves on
Data Sheet.)

Frequency *

50 /60 Hz (47 to 450 Hz)

Current *

115 VAC input

0.49 A typ.

230 VAC input

0.3 A typ.

Power factor

--

Leakage
current

115 VAC input

0.10 mA

0.10 mA

0.10 mA

0.10 mA

230 VAC input

0.20 mA

0.20 mA

0.20 mA

0.20 mA

Inrush
current *
(for a cold
start at 25°)

115 VAC input

16 A typ.

230 VAC input

32 A typ.

Output

Rated Output Current

5 A

2.1 A

1.7 A

1.1 A

Voltage adjustment range *

-10% to 10% (with V. ADJ)

Ripple & Noise
voltage *

100 to 240
VAC input

20 mVp-p max.

20 mVp-p max.

30 mVp-p max.

40 mVp-p max.

Input variation influence *

0.5% max.

Load variation influence *

1.0% max.

Temperature
variation
influence

100 to 240
VAC input

0.03%/°C max.

Startup
time *

115 VAC input

390 ms typ.

340 ms typ.

400 ms typ.

360 ms typ.

230 VAC input

360 ms typ.

350 ms typ.

400 ms typ.

360 ms typ.

Hold time *

115 VAC input

17 ms typ.

22 ms typ.

23 ms typ.

21 ms typ.

230 VAC input

103 ms typ.

113 ms typ.

117 ms typ.

112 ms typ.

Addi-
tional
func-
tions

Overload protection

Yes, automatic reset

Overvoltage protection *

Yes, 115% or higher of rated output voltage, power shut off (shut off the
input voltage and turn on the input again)

Overheat protection

No

Series operation

Yes (For up to 2 Power Supplies, external diodes are required.)

Parallel operation

No (However, backup operation is possible, external diodes are required.)

Remote sensing

No

Remote control

No

Output indicator

Yes (LED: Green)

Insula-
tion

Withstand voltage

3 kVAC for 1 min. (between all input terminals and output terminals)
current cutoff 20 mA

2 kVAC for 1 min. (between all input terminals and PE terminals) current
cutoff 20 mA

1 kVAC for 1 min. (between all output terminals and PE terminals) current
cutoff 20 mA

Insulation resistance

100 MΩ min. (between all output terminals and all input terminals/PE
terminals) at 500 VDC

Envi-
ron-
ment

Ambient operating temperature

-20 to 60°C (Derating is required according to the temperature. Refer
to Derating Curves on Data Sheet.) (with no condensation or icing)

Storage temperature

-40 to 85°C (with no condensation or icing)

Ambient operating humidity

20% to 90% (Storage humidity: 10% to 95%)

Vibration resistance

10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z
directions
10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Z
directions

Shock resistance

150 m/s2, 3 times each in ±X, ±Y, ±Z directions

Relia-
bility

MTBF

135,000 hrs min.

Life expectancy *

10 years min.

Con-
struc-
tion

Dimensions (W × H × D)

Refer to Dimensions.

Weight

250 g max.

Cooling fan

No

Degree of protection

--

Stan-
dards

Harmonic current emissions

Conforms to EN 61000-3-2, GB17625.1

EMI

Conducted
Emissions

Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254

Radiated
Emissions

Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254

EMS

Conforms to EN 61204-3 high severity levels

Safety Standards

Approved Standards
UL: cURus UL 62368-1 (Recognition) OVC II Pol2
CSA: cURus C22.2 No62368-1
CCC: GB4943
Conformed Standards
EN: EN 62368-1 OVC II Pol2
RCM (EN61000-6-4)

Marine Standards

No

SEMI

No

* Refer to Conditions of below.

Power rating

35 W

Output voltage (VDC)

5 V

12 V

15 V

24 V

Efficiency *

115 VAC input

81% typ.

83% typ.

84% typ.

87% typ.

230 VAC input

81% typ.

84% typ.

84% typ.

87% typ.

Input

Voltage range *

Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DC
input is the positive side and safety standards do not apply.) (Derating is
required according to the input voltage. Refer to Derating Curves on
Data Sheet.)

Frequency *

50 /60 Hz (47 to 450 Hz)

Current *

115 VAC input

0.66 A typ.

230 VAC input

0.41 A typ.

Power factor

--

Leakage
current

115 VAC input

0.15 mA

0.15 mA

0.15 mA

0.15 mA

230 VAC input

0.30 mA

0.25 mA

0.25 mA

0.25 mA

Inrush
current *
(for a cold
start at 25°)

115 VAC input

16 A typ.

230 VAC input

32 A typ.

Output

Rated Output Current

7 A

3 A

2.4 A

1.5 A

Voltage adjustment range *

-10% to 10% (with V. ADJ)

Ripple & Noise
voltage *

100 to 240
VAC input

80 mVp-p max.

90 mVp-p max.

90 mVp-p max.

80 mVp-p max.

Input variation influence *

0.5% max.

Load variation influence *

1.0% max.

Temperature
variation
influence

100 to 240
VAC input

0.03%/°C max.

Startup
time *

115 VAC input

750 ms typ.

750 ms typ.

760 ms typ.

770 ms typ.

230 VAC input

700 ms typ.

690 ms typ.

710 ms typ.

720 ms typ.

Hold time *

115 VAC input

13 ms typ.

14 ms typ.

14 ms typ.

15 ms typ.

230 VAC input

74 ms typ.

75 ms typ.

75 ms typ.

79 ms typ.

Addi-
tional
func-
tions

Overload protection

Yes, automatic reset

Overvoltage protection *

Yes, 115% or higher of rated output voltage, power shut off (shut off the
input voltage and turn on the input again)

Overheat protection

No

Series operation

Yes (For up to 2 Power Supplies, external diodes are required.)

Parallel operation

No (However, backup operation is possible, external diodes are required.)

Remote sensing

No

Remote control

No

Output indicator

Yes (LED: Green)

Insula-
tion

Withstand voltage

3 kVAC for 1 min. (between all input terminals and output terminals)
current cutoff 20 mA

2 kVAC for 1 min. (between all input terminals and PE terminals) current
cutoff 20 mA

1 kVAC for 1 min. (between all output terminals and PE terminals) current
cutoff 20 mA

Insulation resistance

100 MΩ min. (between all output terminals and all input terminals/PE
terminals) at 500 VDC

Envi-
ron-
ment

Ambient operating temperature

-20 to 60°C (Derating is required according to the temperature. Refer
to Derating Curves on Data Sheet.) (with no condensation or icing)

Storage temperature

-40 to 85°C (with no condensation or icing)

Ambient operating humidity

20% to 90% (Storage humidity: 10% to 95%)

Vibration resistance

10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z
directions
10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Z
directions

Shock resistance

150 m/s2, 3 times each in ±X, ±Y, ±Z directions

Relia-
bility

MTBF

135,000 hrs min.

Life expectancy *

10 years min.

Con-
struc-
tion

Dimensions (W × H × D)

Refer to Dimensions.

Weight

250 g max.

Cooling fan

No

Degree of protection

--

Stan-
dards

Harmonic current emissions

Conforms to EN 61000-3-2, GB17625.1

EMI

Conducted
Emissions

Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254

Radiated
Emissions

Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254

EMS

Conforms to EN 61204-3 high severity levels

Safety Standards

Approved Standards
UL: cURus UL 62368-1 (Recognition) OVC II Pol2
CSA: cURus C22.2 No62368-1
CCC: GB4943
Conformed Standards
EN: EN 62368-1 OVC II Pol2
RCM (EN61000-6-4)

Marine Standards

No

SEMI

No

* Please contact us about more specification details for 35/50/75/100/150/200/350-W.