Power rating | 15 W |
Output voltage (VDC) | 5 V | 12 V | 15 V | 24 V |
Efficiency * | 115 VAC input | 80% typ. | 84% typ. | 84% typ. | 85% typ. |
230 VAC input | 82% typ. | 85% typ. | 86% typ. | 87% typ. |
Input | Voltage range * | Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DC input is the positive side and safety standards do not apply.) (Derating is required according to the input voltage. Refer to Derating Curves on Data Sheet.) |
Frequency * | 50 /60 Hz (47 to 450 Hz) |
Current * | 115 VAC input | 0.3 A typ. |
230 VAC input | 0.19 A typ. |
Power factor | -- |
Leakage current | 115 VAC input | 0.05 mA | 0.05 mA | 0.05 mA | 0.05 mA |
230 VAC input | 0.10 mA | 0.10 mA | 0.10 mA | 0.10 mA |
Inrush current * (for a cold start at 25°) | 115 VAC input | 16 A typ. |
230 VAC input | 32 A typ. |
Output | Rated Output Current | 3 A | 1.3 A | 1 A | 0.7 A |
Voltage adjustment range * | -10% to 10% (with V. ADJ) |
Ripple & Noise voltage * | 100 to 240 VAC input | 30 mVp-p max. | 30 mVp-p max. | 40 mVp-p max. | 30 mVp-p max. |
Input variation influence * | 0.5% max. |
Load variation influence * | 1.0% max. |
Temperature variation influence | 100 to 240 VAC input | 0.03%/°C max. |
Startup time * | 115 VAC input | 490 ms typ. | 500 ms typ. | 470 ms typ. | 480 ms typ. |
230 VAC input | 470 ms typ. | 480 ms typ. | 450 ms typ. | 460 ms typ. |
Hold time * | 115 VAC input | 14 ms typ. | 16 ms typ. | 18 ms typ. | 15 ms typ. |
230 VAC input | 83 ms typ. | 87 ms typ. | 92 ms typ. | 79 ms typ. |
Addi- tional func- tions | Overload protection | Yes, automatic reset |
Overvoltage protection * | Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) |
Overheat protection | No |
Series operation | Yes (For up to 2 Power Supplies, external diodes are required.) |
Parallel operation | No (However, backup operation is possible, external diodes are required.) |
Remote sensing | No |
Remote control | No |
Output indicator | Yes (LED: Green) |
Insula- tion | Withstand voltage | 3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA |
2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA |
1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA |
Insulation resistance | 100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC |
Envi- ron- ment | Ambient operating temperature | -20 to 60°C (Derating is required according to the temperature. Refer to Derating Curves on Data Sheet.) (with no condensation or icing) |
Storage temperature | -40 to 85°C (with no condensation or icing) |
Ambient operating humidity | 20% to 90% (Storage humidity: 10% to 95%) |
Vibration resistance | 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z directions 10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Z directions |
Shock resistance | 150 m/s2, 3 times each in ±X, ±Y, ±Z directions |
Relia- bility | MTBF | 135,000 hrs min. |
Life expectancy * | 10 years min. |
Con- struc- tion | Dimensions (W × H × D) | Refer to Dimensions. |
Weight | 150 g max. |
Cooling fan | No |
Degree of protection | -- |
Stan- dards | Harmonic current emissions | Conforms to EN 61000-3-2, GB17625.1 |
EMI | Conducted Emissions | Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 |
Radiated Emissions | Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 |
EMS | Conforms to EN 61204-3 high severity levels |
Safety Standards | Approved Standards UL: cURus UL 62368-1 (Recognition) OVC II Pol2 CSA: cURus C22.2 No62368-1 CCC: GB4943 Conformed Standards EN: EN 62368-1 OVC II Pol2 RCM (EN61000-6-4) |
Marine Standards | No |
SEMI | No |