Input specification | 100 to 240 V input |
Power ratings *1 | 300 W | 600 W |
Efficiency | 5 V Models | 75% min. | 76% min. |
12 V Models | 77% min. | 76% min. |
24 V Models | 79% min. | 78% min. |
48 V Models | 78% min. | 79% min. |
Input | Voltage *2 | 100 to 240 VAC (allowable range: 85 to 264 VAC, 80 to 370 VDC *8) |
Frequency *2 | 50/60 Hz (47 to 63 Hz) |
Current *3 | 100 V input | 4.5 A max. | 8.7 A max. |
200 V input | 2.2 A max. | 4.3 A max. |
Power factor *3 | 0.9 min. |
Harmonic current emissions | Conforms to EN61000-3-2 |
Leakage current *3 | 100 V input | 0.5 mA max. |
200 V input | 1 mA max. |
Inrush current (for a cold start at 25 °C) *3 | 100 V input | 17.5 A max. |
200 V input | 35 A max. |
Output *4 | Voltage adjustment range *5 | -10% to 15% (with V. ADJ) (5 V, 48 V models: ±10%) |
Ripple *3 | 3% (p-p) max. (5 V) *12 2% (p-p) max. (12 V) *12 2% (p-p) max. (24 V or 48 V types) |
Input variation influence | 0.4% max. |
Load variation influence | 0.8% max. (0 to 100% load, rated input voltage) |
Temperature variation influence | 0.05%/ °C max. |
Startup time | 1,000 ms max. |
Hold time *3 | 20 ms min. |
Addi- tional func- tions | Overload protection *6 | 105% to 160% of rated load current, voltage drop, intermittent, automatic reset. |
Overvoltage protection *7 | Yes |
Overheat protection | Yes |
Parallel operation | Yes (up to 5 Power Supplies) |
Series operation | Yes (For up to two Power Supplies; external diodes required.) |
Remote sensing | Supported |
Remote control | Supported |
Alarm detection indication | Yes (color: red) |
Alarm output | Provided, open-collector output, 30 VDC max, 50 mA max. |
Other | Ambient operating temperature | Refer to the derating curve in Engineering Data on Catalog. (with no icing or condensation). |
Storage temperature | - 25 to 75 °C (with no icing or condensation) |
Ambient operating humidity | 25% to 85% (Storage humidity: 25% to 90%) |
Dielectric strength | 3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA) 2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA) 1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 100 mA) 100 VAC for 1 min. (between all outputs and RC terminals; detection current: 100 mA) 500 VAC for 1 min. (between all outputs and ALM terminals; detection current: 20 mA) |
Insulation resistance | 100 MΩ min. (between all outputs and all inputs/PE terminals) at 500 VDC |
Vibration resistance | 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions |
Shock resistance | 150 m/s2, 3 times each in ±X, ±Y, ±Z directions *10 |
Output indicator | Yes (Color: Green) |
EMI | Conducted Emissions *3 | Conforms to EN 55011 Group 1 Class B and based on FCC Class B *11 |
Radiated Emissions | Conforms to EN 55011 Group 1 Class B *11 |
EMS | Electrostatic Discharge | Conforms to EN61000-4-2 |
Radiated Electromagnetic Field | Conforms to EN61000-4-3 |
Electrical Fast Transient/Burst | Conforms to EN61000-4-4 |
Surge | Conforms to EN61000-4-5 |
Conducted Disturbance | Conforms to EN61000-4-6 |
Voltage Dips/Short Interruptions | Conforms to EN61000-4-11 |
Approved standards *8 | UL UR: UL 508 (Recognition) *13 UL Listed: UL508 (Listing) *14 UL UR: UL 62368-1 (Recognition) |
cUR: CSA C22.2 No.107.1, CSA C22.2 No. 62368-1 |
Conformed standards *8 | EN: EN 62477-1 Over voltage category III, EN 62368-1 Terminal block: Based on DIN 50274) |
SEMI | SEMI F47-0706 (200-VAC input) |
Weight | 1,200 g max. *9 | 1,800 g max. *9 |