Model | GL-R39F |
Detection capability | ø14 mm |
Total length | 400mm |
No. of beam | 39 |
Detection height | 380mm |
Protection height | 404mm |
Beam axis spacing/Lens diameter | 10 mm / ø4 |
Detecting distance | 0.2 to 10 m*1 |
Effective aperture angle | Max. ±2.5° (When operating distance is 3 m or more) |
Light source | Infrared LED (870 nm) |
Response time (OSSD) (ms) | Wire synchronisation, One-line or Optical synchronisation system (Channel 0) | ON→OFF | 8.6 |
OFF→ON | 51.8*2 |
All blocked→ON | 71.3*3 |
Optical synchronisation system (Channel A or B) | ON→OFF | 12.1 |
OFF→ON | 56.9*2 |
All blocked→ON | 85.1*3 |
Detection mode | Turns on when no interruptions are present in the detection zone |
Synchronisation between the transmitter and receiver | Optical synchronisation or Wire synchronisation (Determined by wiring) |
Light interference prevention function | Prevents mutual interference in up to two GL-R systems. Optical synchronization: prevented by Channel A and B with setting switch Wire synchronization: prevented automatically |
Control output (OSSD output) | Output | 2 transistor outputs. (PNP or NPN is determined by the cable type) |
Max. load current | 500 mA*4 |
Residual voltage (during ON) | Max. 2.5 V (with a cable length of 5 m) |
OFF state voltage | Max. 2.0 V (with a cable length of 5 m) |
Leakage current | Max. 200 µA |
Max. capacitive load | 2.2 µF |
Load wiring resistance | Max. 2.5 Ω |
Supplemental output (Non-safety-related output) | AUX | transistor outputs. (PNP or NPN is determined by the cable type) Load current: Max. 50 mA, Residual voltage: Max. 2.5 V (with a cable length of 5 m) |
Error output |
Muting lamp output | Incandescent lamp (24 VDC, 1 to 5.5 W) LED lamp (load current: 10 to 230 mA) can be connected. |
External input | When using a PNP output cable | EDM input Wait input Reset input Muting input 1, 2 Override input | ON voltage: 10 to 30 V OFF voltage: Open or 0 to 3 V Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only) |
When using an NPN output cable | ON voltage: 0 to 3 V OFF voltage: Open or 10 V or more Up to the power voltage Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only) |
Power supply | Power voltage | 24 VDC ±20%, ripple (P-P) 10% or less, Class 2 |
Current consumption (Max.) (mA) | Transmitter | 57 |
Receiver | 72 |
Protection circuit | Reverse current protection, short-circuit protection for each output, surge protection for each output |
Approved standards | EMC | EMS | IEC61496-1, EN61496-1, UL61496-1 |
EMI | EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA |
Safety | IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) IEC61496-2, EN61496-2, UL61496-2 (Type 4 AOPD) IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL CL3) EN ISO13849-1:2015 (Category 4, PLe) UL508 UL1998 |
Environmental resistance | Enclosure rating | IP65/IP67 (IEC60529) |
Overvoltage category | II |
Ambient light | Incandescent lamp: 3,000 lux or less, Sunlight: 20,000 lux or less |
Operating ambient temperature | -10 to +55 °C (No freezing) |
Storage temperature | -25 to +60 °C (No freezing) |
Operating relative humidity | 15 to 85 % RH (No condensation) |
Storage relative humidity | 15 to 95 % RH |