Model | LM-X100L |
Type | Head |
Image sensor | 1", 20-megapixel monochrome CMOS |
Receiver lens | Double telecentric lens |
Image measurement | Field of view | Wide-field measurement mode | 325 mm × 175 mm |
High-precision measurement mode | 306 mm × 156 mm |
Minimum display unit | 0.1 μm |
Repeatability | Inside camera's field of view (2σ) | Wide-field measurement mode | ±0.5 μm |
High-precision measurement mode | ±0.1 μm |
With stage movement | X/Y axis (E1) | ±0.9 μm |
X/Y plane (E2) |
Measurement accuracy | Inside camera's field of view (2σ) | Wide-field measurement mode | ±2 μm *1 |
High-precision measurement mode | ±0.7 μm *2 |
With stage movement | X/Y axis (E1) | ±(1.8 + 0.02 L) μm *3 |
X/Y plane (E2) | ±(2.8 + 0.02 L) μm *3 |
AF height measurement | Repeatability | ±2 μm |
Measurement accuracy (EUZ,MPE) | ±(4.8 + 0.04 L) μm *4 |
Laser height measurement | Measurable range (X/Y) | 239 mm × 146 mm |
Minimum display unit | 0.1 μm |
Repeatability | ±0.6 μm *5 |
Measurement accuracy (EUZ,MPE) | ±(4.8 + 0.04 L) μm *4 |
Spot diameter | ø50 μm |
Laser class | Class 1 |
External remote input | Non-voltage input (with and without contact) |
External output | OK/NG/FAIL/MEAS. | PhotoMOS output Rated load: 24 VDC, 0.5 A ON resistance: 50 mΩ or lower |
Illumination system | Transparent | Telecentric transparent green LED illumination |
Ring | Four division, multi-angle colour LED/ white LED illumination (electric) Slit ring (directivity) side green LED illumination (electric) Telecentric coaxial white LED illumination |
External illumination control | Intensity control | PWM control, 100 kHz |
Output voltage | 12 VDC |
Output current | 1.6 A (max.) |
XY stage | Moving range | 300 mm × 150 mm (motorised) |
Withstand load | 7 kg |
Z stage | Moving range | 75 mm (electric) |
Power supply | Power voltage | 100 to 240 VAC ±10% (50/60 Hz) |
Power consumption | 150 VA or less |
Environmental resistance | Ambient temperature | +10 to 35°C *6 |
Relative humidity | 20 to 80% RH (no condensation) |
Overvoltage category | ll |
Pollution degree | 2 |
Weight | Approx. 34 kg |
*1 In the range of 20 mm × 20 mm, within the operating ambient temperature range of +23°C ±1°C at the focused focal point position *2 In the range of 5 mm × 5 mm, within the operating ambient temperature range of +23°C ±1°C at the focused focal point position *3 In accordance with ISO 10360-7, within the operating ambient temperature range of +23°C ±1°C at the focused focal point position, and with a load weighing 2 kg or less on the stage (L = amount of X/Y stage movement in mm units) *4 In accordance with ISO 10360-7, for plane-to-point height, within the operating ambient temperature range of +23°C ±1°C, set to measurement of a target with a maximum height of 50 mm or less, (L = amount of Z stage movement in mm units) *5 In-house measurement of a standard target at an operating ambient temperature of +23°C ±1°C *6 With an XY-motorised stage travel speed of 80 mm/s: +15 to 35°C |