KEYENCE
KV-NC32EX
Expansion Input Unit 32-input switching 5V/24V DC connector type
Specifications:
Model | KV-NC32EX |
Expansion input unit | External connection method | Connector |
Input Points | 32 points |
Input terminals | 24 VDC mode, 5 VDC mode |
Maximum input voltage | 26.4 VDC |
Input rated voltage | 24 VDC mode | 5.2 mA |
5 VDC mode | 1 mA |
Minimum ON voltage | 24 VDC mode | 19 V |
5 VDC mode | 3.5 V |
Maximum OFF voltage | 24 VDC mode | 1.5 mA |
5 VDC mode | 1.5 V |
Common method | 32 points/1 common (2 terminals)*1 |
Input time constant (four-level switching) | Input time constant setting | OFF to ON: Typ. | 25 µs: 10 µs 300 µs : 240 µs 1 ms: 1 ms 10 ms: 10 ms |
OFF to ON: Max. | 25 µs: 50 µs 300 µs : 290 µs 1 ms: 1.2 ms 10 ms: 11 ms |
ON to OFF: Typ. | 25 µs: 50 µs 300 µs : 280 µs 1 ms: 1 ms 10 ms: 10 ms |
ON to OFF: Max. | 25 µs: 150 µs 300 µs : 390 µs 1 ms: 1.2 ms 10 ms: 11ms |
Input impedance | 4.4 kΩ |
Internal current consumption | 20 mA or less |
Weight | Approx. 110 g |
*1 The KV-NX16EX and KV-NC32EX have 2 COM terminals, but these are shared internally. |