KEYENCE

KEYENCE KL-2TF PID Temperature Adjustment Unit (2-channel)

KEYENCEKL-2TFPID Temperature Adjustment Unit (2-channel)Specifications:ModelKL-2TFPerformance specificationsSampling rate125 ms/ch (250 ms/2 ch)Temperature sensor typeThermocouplesK, J, T, E, R, B, N,

  • model:

KEYENCE

KL-2TF

PID Temperature Adjustment Unit (2-channel)


Specifications:

Model

KL-2TF

Performance specifications

Sampling rate

125 ms/ch (250 ms/2 ch)

Temperature sensor type

Thermocouples

K, J, T, E, R, B, N, S, W5Re/W26Re

Platinum resistance thermometer

JPt100, Pt100

Indication accuracy

±0.3% of F.S. ± 1 digit (at 25°C ± 5°C), ±0.7% of F.S. ± 1 digit (between 0 and 60°C)

Current consumption

160mA or less

Control cycle

1 to 100s

Power voltage

24 VDC ± 10%

Operation mode

PID control (with auto tuning and 3-mode stabilizer functions), heating and cooling PID control (with auto tuning and 3-mode stabilizer functions), on/off control

External calibration input signal

Thermocouple, platinum resistance thermometer*1

Enclosure rating

IP66f (when attached to a panel, operation part of the front surface only)

Weight

approx 210g

Number of temperature inputs

2ch