Model | KL-LC1 |
General specifications | Measurement type | Load cell |
Power voltage | 24 VDC ± 10%, Class 2 |
Operating ambient temperature | 0 to +50°C (no freezing) |
Operating ambient humidity | 35 to 85%RH(no condensation) |
Ambient temperature for storage | -20 to +70°C |
Operating environment | Minimal amount of dust and corrosive gas present |
Measurement category | - |
Wire temperature rating | +60°C or more |
Noise immunity | 1,500 Vp-p or more, pulse width: 1 µs, 50 ns (by way of a noise simulator), conforms to IEC standards (IEC 61000-4-2/-3/-4/-6) |
Withstand voltage | 1,500 VAC for 1 minute (between the power supply terminal and each terminal and between all the terminals and the case) |
Insulation resistance | 100 MΩ or more (tested with a 500 VDC megger, between the power supply terminal and each I/O terminal and between all the terminals and the case) |
Internal current consumption (excluding current for driving input circuits) | 230mA or less |
Shock resistance | Conforms to JIS B 3502 and IEC 61131-2, 147 m/s2, operating time: 11 ms, 3 times in each of the 3 directions |
Pollution degree | 2 |
Vibration resistance | Intermittent vibration | Frequency: 10 to 57 Hz | Amplitude: 0.075 mm*1 |
Frequency: 57 to 150 Hz | Acceleration: 9.8 m/s2*1 |
Continuous vibration | Frequency: 10 to 57 Hz | Amplitude: 0.035 mm*1 |
Frequency: 57 to 150 Hz | Acceleration: 4.9 m/s2*1 |
Weight | approx 350g |
Performance specifications | Number of channels | 1CH |
Number of ranges | 4 |
Range switching | Setting: Use the setting switch. |
Sampling rate | 1 ms (1,000 times/sec.) |
Input range*2 | Range 1: 0.5 mV/V, range 2: 1.0 mV/V, range 3: 2.0 mV/V, range 4: 3.0 mV/V*2*3 |
Input range | 5V | Range 1: 0.5 mV/V | -2.5 to +2.5 mV*2*3 |
Range 2: 1.0 mV/V | -5.0 to +5.0 mV*2*3 |
Range 3: 2.0 mV/V | -10.0 to +10.0 mV*2*3 |
Range 4: 3.0 mV/V | -15.0 to +15.0 mV*2*3 |
10 V | Range 1: 0.5 mV/V | -5.0 to +5.0 mV*2*3 |
Range 2: 1.0 mV/V | -10.0 to +10.0 mV*2*3 |
Range 3: 2.0 mV/V | -20.0 to +20.0 mV*2*3 |
Range 4: 3.0 mV/V | -30.0 to +30.0 mV*2*3 |
Resolution | 5V | Range 1: 0.5 mV/V | 0.5 µV, 1/10000 |
Range 2: 1.0 mV/V | 1.0 µV, 1/10000 |
Range 3: 2.0 mV/V | 2.0 µV, 1/10000 |
Range 4: 3.0 mV/V | 3.0 µV, 1/10000 |
10 V | Range 1: 0.5 mV/V | 0.5 µV, 1/20000 |
Range 2: 1.0 mV/V | 1.0 µV, 1/20000 |
Range 3: 2.0 mV/V | 2.0 µV, 1/20000 |
Range 4: 3.0 mV/V | 3.0 µV, 1/20000 |
Linearity (0 to 50°C) | ±0.2% of F.S. ± 1 digit |
Zero-drift (0 to 50°C) | ±0.4% of F.S. ± 1 digit |
Control input | 2 (Parameters are used to switch between the KL input, peak/bottom hold control input, and 0-point adjustment input.) |
Controloutput | 2 transistor (NPN open-collector) outputs (Parameters are used to switch between the KL output and comparator output.) |
Setting data | Recorded to the EEPROM (rewritable 1,000,000 times) |
Other functions | Hold (peak and bottom), 0-point adjustment, comparator output, filter setting (LPF and HPF), time average (simple and moving), calibration setting (real and theoretical), display unit changing, lock |
Compatible sensor | 350 Ω |
Control I/O specifications | External calibration input signal | Number of inputs | 2 |
Maximum input voltage | DC26.4V |
Input rated voltage | DC24V 5.3mA |
Minimum ON voltage | 19V |
Maximum OFF current | 1.5mA |
Common ground | 2/common |
Input time constant | 10ms |
Control output | Number of outputs | 2 |
Output | Transistor NPN output |
Rated load | DC30V 0.1A |
Peak load current | 0.2A |
Leakage current (at OFF) | 100 µA or less |
Residual voltage (at ON) | DC0.8V or less |
Common ground | 2/common |
ON/OFF response time | Off to on: 10 µs or less (between 5 and 100 mA), on to off: 50 µs or less (between 5 and 100 mA) |
KL link specifications | Supported master units | Model: KL-N20V, supported PLC: KEYENCE KV-1000/700; model: KL-N10V, supported PLC: KEYENCE KV-10/16/24/40; model: KV-P16*L (built-in PLC), supported PLC: KEYENCE; model: KL-N20A, supported PLC: Mitsubishi AnA, AnA, AnU, QnA, AnSH, and Q2AS; model: KL-N20C, supported PLC: Omron C200H/HS, SYSMAC α, and CS1 (excluding the C200H-02/22), KEYENCE VT2-12F/10F/10T/10S/8T/8S/7S/5T/5S/5M and DT-100 |
Communication address | 00 H to FE H(0 to 254) |
Number of occupied words | EASY mode: reception (KL to PLC): 5 words, transmission (PLC to KL): 3 words; FULL mode: reception (KL to PLC): 7 words, transmission (PLC to KL): 5 words*4 |
Communication speed | 2.5 Mbps, 625 kbps, 156 kbps (set with parameters)*5 |
*1 Conforms to JIS B 3502, IEC61131-2 Number of sweeps: 10 times respectively in the X, Y, and Z directions (80 minutes) *2 Select with the setting switch. *3 If a signal that exceeds the input range has been entered, FFFF (-FFFF) will be displayed. Also, when calibration settings are in effect, if the measurement value exceeds the displayable range with signals in the input range, EFFF (-EFFF) will be displayed. *4 In the direction of transmission/reception when seen from the master unit. *5 The <> do not support a communication speed of 5 Mbps. |