Model | KV-RC16BR |
General specifications | Vibration resistance | Intermittent vibration | Frequency:5 to 9Hz | Half amplitude: 3.5 mm*1 |
Frequency:9 to 150Hz | Acceleration: 9.8 m/s2*1 |
Continuous Vibration | Frequency:5 to 9Hz | Half amplitude: 1.75 mm*1 |
Frequency:9 to 150Hz | Acceleration: 4.9 m/s2*1 |
Current consumption | At 11.4 V: 390 mA or less, at 26.4 V: 150 mA or less |
Power voltage | Rated voltage: 12 to 24 VDC, supply voltage range: 11.4 to 26.4 VDC |
Operating ambient temperature | 0 to +60°C (no freezing) |
Operating ambient humidity | 10 to 95%RH(no condensation) |
Ambient temperature for storage | -20 to +75°C |
Approved standards | Overvoltage category | II |
Pollution degree | 2 |
Storage relative humidity | 10 to 95%RH(no condensation) |
Approved standards | CE marking | EMI: EN55011 Class A, EMS: EN61131-2, low voltage directive: EN61131-2*2 |
Operating environment | Minimal amount of dust and corrosive gas present |
Altitude | 2000m or less |
Approved standards | FCC | FCC Part15B class A |
UL | UL :UL508 CSA :CAN/CSA22、2 No.14 |
ICES | ICES-003 Issue4 |
Noise immunity | 1,500 Vp-p or more, pulse width: 1 µs, 50 ns (by way of a noise simulator), conforms to IEC standards (IEC 61131-2) |
Withstand voltage | 1,500 VAC for 1 minute (between the power supply terminal and the communication terminal, between the power supply terminal and the I/O terminals, and between all the external terminals and the case) |
Enclosure rating | IP2X |
Insulation resistance | 100 MΩ or more (tested with a 500 VDC megger, between the power supply terminal and the I/O terminal) |
CC-Link specifications | Supported version: 1.10, number of occupied stations: 1, station type: remote I/O station |
Output specifications | relay output | Rated voltage | AC240V/DC24V |
Rated output current | 240 VAC, 24 VDC, 2 A/output, 4 A/common |
ON resistance | 50 mΩ or less |
ON delay time | 10ms or less |
Insulation | Relay isolation |
OFF delay time | 10ms or less |
Weight | approx 290g |
*1 Conforms to JIS B 3502 IEC61131-2 Number of sweeps: 10 times respectively in the X, Y, and Z directions, 100 minutes *2 The only models that are required to support the low voltage directive are the KV-RC16BR and the KV-RC8BXR. Other I/O units are not required to support the low voltage directive. |