Model | KV-RC32BX |
General specifications | Vibration resistance | Intermittent vibration | Frequency:5 to 9Hz | Half amplitude: 3.5 mm*1 |
Frequency:9 to 150Hz | Acceleration: 9.8 m/s2*1 |
Continuous Vibration | Frequency:5 to 9Hz | Half amplitude: 1.75 mm*1 |
Frequency:9 to 150Hz | Acceleration: 4.9 m/s2*1 |
Current consumption | At 11.4 V: 160 mA or less, at 26.4 V: 80 mA or less |
Power voltage | Rated voltage: 12 to 24 VDC, supply voltage range: 11.4 to 26.4 VDC |
Operating ambient temperature | 0 to +60°C (no freezing) |
Operating ambient humidity | 10 to 95%RH(no condensation) |
Ambient temperature for storage | -20 to +75°C |
Approved standards | Overvoltage category | II |
Pollution degree | 2 |
Storage relative humidity | 10 to 95%RH(no condensation) |
Approved standards | CE marking | EMI: EN55011 Class A, EMS: EN61131-2, low voltage directive: EN61131-2*2 |
Operating environment | Minimal amount of dust and corrosive gas present |
Altitude | 2000m or less |
Approved standards | FCC | FCC Part15B class A |
UL | UL :UL508 CSA :CAN/CSA22、2 No.14 |
ICES | ICES-003 Issue4 |
Noise immunity | 1,500 Vp-p or more, pulse width: 1 µs, 50 ns (by way of a noise simulator), conforms to IEC standards (IEC 61131-2) |
Withstand voltage | 1,500 VAC for 1 minute (between the power supply terminal and the communication terminal, between the power supply terminal and the I/O terminals, and between all the external terminals and the case) |
Enclosure rating | IP2X |
Insulation resistance | 100 MΩ or more (tested with a 500 VDC megger, between the power supply terminal and the I/O terminal) |
CC-Link specifications | Supported version: 1.10, number of occupied stations: 1, station type: remote I/O station |
Input specifications | 24 V mode | Input maximum rating | DC26.4V |
Input voltage | DC24V approx 5.3mA |
Minimum ON voltage | 19V |
Minimum ON current | - |
Maximum OFF voltage |
Maximum OFF current | 2.0mA |
Input impedance | 4.3 kΩ |
Insulation system | Photocoupler isolation |
Input time constant (switching method) | · 0.2 ms · 1.5 ms · 10 ms |
12 V mode | Input maximum rating | DC26.4V*3 |
Input voltage | DC12V approx 2.5mA*3 |
Minimum ON voltage | 3.0V*3 |
Minimum ON current | -*3 |
Maximum OFF voltage | 1.0V*3 |
Maximum OFF current | -*3 |
Input impedance | 4.3 kΩ*3 |
Insulation system | Photocoupler isolation*3 |
Input time constant(switching method) | · 0.2 ms · 1.5 ms · 10 ms |
5 V mode | Input maximum rating | DC26.4V*4 |
Input voltage | DC5V approx 0.9mA*4 |
Minimum ON voltage | 2.5V*4 |
Minimum ON current | -*4 |
Maximum OFF voltagex | 0.8V*4 |
Maximum OFF current | -*4 |
Input impedance | 4.3 kΩ*4 |
Insulation system | Photocoupler isolation*4 |
Input time constant(switching method) | · 0.2 ms · 1.5 ms · 10 ms |
Weight | approx 250g |
*1 Conforms to JIS B 3502 IEC61131-2 Number of sweeps: 10 times respectively in the X, Y, and Z directions, 100 minutes *2 The only models that are required to support the low voltage directive are the KV-RC16BR and the KV-RC8BXR. Other I/O units are not required to support the low voltage directive. *3 In 12 V mode, only the KV-RC8BXT and KV-RC16BXT are selectable. *4 In 5 V mode, only the KV-RC16BX, KV-RC32BX, and KV-RC8BXR are selectable. |