Model | SV-075L2 |
Power supply/current capacity and power loss | Maximum applicable motor capacity Single-phase 100 VAC | ― |
Maximum applicable motor capacity Three-phase 200 VAC | 750 W |
Maximum applicable motor capacity Single-phase 200 VAC |
Power capacity (VA) per amplifier Single-phase 100 VAC | ― |
Power capacity (VA) per amplifier Three-phase 200 VAC | 1600 VA |
Power capacity (VA) per amplifier Single-phase 200 VAC | 1900 VA |
Output current Continuous | Single-phase 100 VAC | ― |
Three-phase 200 VAC | 5.5 Arms |
Single-phase 200 VAC |
Output current Maximum | Single-phase 100 VAC | ― |
Three-phase 200 VAC | 16.9 Arms |
Single-phase 200 VAC |
Main circuit power loss Single-phase 100 VAC | ― |
Main circuit power loss Three-phase 200 VAC | 43.8 W |
Main circuit power loss Single-phase 200 VAC | 52.7 W |
Built-in regenerative resistor power loss Single-phase 100 VAC | ― |
Built-in regenerative resistor power loss Three-phase 200 VAC | 8 W |
Built-in regenerative resistor power loss Single-phase 200 VAC |
Control circuit power loss Single-phase 100 VAC | ― |
Control circuit power loss Three-phase 200 VAC | 17 W |
Control circuit power loss Single-phase 200 VAC |
Total power loss Single-phase 100 VAC | ― |
Total power loss Three-phase 200 VAC | 68.8 W |
Total power loss Single-phase 200 VAC | 77.7 W |
Input rated current | Main circuit Single-phase 100 VAC | ― |
Main circuit Three-phase 200 VAC | 6 Arms |
Main circuit Single-phase 200 VAC | 9 Arms |
Control circuit Single-phase 100 VAC | ― |
Control circuit Three-phase 200 VAC | 0.2 Arms |
Control circuit Single-phase 200 VAC |
Rush current | Main circuit Single-phase 100 VAC | ―*1 |
Main circuit Three-phase 200 VAC | 33 A*1 |
Main circuit Single-phase 200 VAC |
Control circuit Single-phase 100 VAC | ―*1 |
Control circuit Three-phase 200 VAC | 33 A*1 |
Control circuit Single-phase 200 VAC |
General specifications | Type | For 200 V |
Capacity | 750W |
Input power supply | Voltage/frequency | Main circuit | 3-phase (or single-phase) 200 to 230 VAC, 50/60 Hz, 270 to 320 VDC |
Control circuit | Single-phase 200 to 230 VAC, 50/60 Hz |
Main circuit/control circuit | Allowable voltage fluctuation | 170 to 253 VAC |
Allowable frequency fluctuation | ±5% or less |
Allowable instantaneous outage time | Main circuit | Full-stop (100% down): 0.5 cycles, half-stop (50% down): 1 cycle |
Control circuit | Approx 100ms |
Overvoltage category | III |
Control method | 3-phase full-wave rectification, IGBT, PWM control, sine wave current drive method |
Feedback | 20-bit serial encoder (incremental, absolute) communication |
Operating environment | Operating ambient temperature | 0 to +55°C (no freezing) |
Ambient storage temperature | -20 to +70°C (no freezing) |
Ambient operating/storage humidity | 90%RH or less (no condensation) |
Vibration resistance | 4.9 m/s2 (conforms to JIS C 60068-2-6) |
Shock resistance | 19.6 m/s2 (conforms to JIS C 60068-2-27) |
Operating atmosphere (enclosure rating/pollution degree) | Pollution degree: 2 (within a control panel that has a rating of IP54 or higher), however, · No corrosive or flammable gas present · A location that is not subject to water, oil, or drugs · No dust present |
Altitude | 1,000 m or less above sea level |
Approved standards | UL/CSA standards | UL508C, CSA C22.2 number 14 |
CE marking | Low-voltage directive | EN50178 |
EMI | EN55011 Class A, EN61800-3 |
EMS | EN61800-3, EN61000-6-2 |
North American EMI standards | FCC Part 15 B, ICES-003, Class A |
Structure | Type | Base mounting attachment |
Protection | Open, forced |
Lowest insulation resistance value | 1 MΩ or more, tested with a 500 VDC megger |
Insulation withstand voltage | 1,500 VAC or more (between the primary side and the earth terminal), 1,800 VAC or more (between the primary side and the secondary side) |
Weight | Approx 1.5kg |
Performance specifications | Performance | Speed control range | 1 to 5,000 (under the condition that the load torque is less than or equal to the rated torque) |
Speed fluctuation rate | During load fluctuation | ±0.01% or less with a load fluctuation between 0 and 100% (at the rated rotation speed) |
When the voltage of the main circuit fluctuates | 0% at the rated voltage ±10% (at the rated rotation speed) |
When the ambient temperature fluctuates | ±0.1% or less when the ambient temperature is between 0 and +50°C (at the rated rotation speed) |
Torque control accuracy (reproducibility) | ±1% |
Speed frequency response | 1.6 kHz (when JL = JM) * JL: load moment of inertia (motor axis conversion), JM: motor moment of inertia |
Dynamic brake | Built-in |
Analogue monitor output for observation | Monitor output such as motor rotation speed and torque instruction for observations, number of built-in channels: 2 |
Regenerative resistor | Built-in regenerative resistor | Present (40 W) |
External regenerative resistor | OP-84399 (220 W*2) |
Display function | Access window | Status monitor, parameter settings, calibration, etc. |
CHARGE display LED | CHARGE LED (orange) for checking the main circuit power supply input |
Status | Servo on, instruction input in progress, warning, MECHATROLINK-II communication in progress |
Communication function | USB communication | Function | Status display, parameter settings, calibration, etc. |
Connection device | PC |
Protection function | Overcurrent, overvoltage, insufficient voltage, overload, regeneration error, etc. |
Other functions | Auto calibration, absolute position system, etc. |
I/O specifications | MECHATROLINK-II type | Control I/O | Input signal: Number of channels | 8CH |