Model | RC2-21 |
Type | 1-level preset counter/timer, DC type |
Operation method | Addition, subtraction, addition and subtraction |
Operation mode | Overcount, auto-reset, rotary, comparator |
Return method | Manual, external, automatic (auto reset) |
Display power | 7-segment LED (character height: 14 mm) |
Number of digits | 5 (with zero-suppress function) -9999 to 99999*1 |
Prescale function | A | 1 pulse → 1 to 99 counts |
B | 1 to 99999 pulses → 1 count |
Power off memory time | Lithium battery (service life: Approx 10 years at 20°C) |
Input | System | Individual, command, phase differential |
Mounting method | Flush (panel) mounting |
External calibration input signal | Signal | Non-voltage input (contact or solid-state) (Count input, inhibit input, reset input) |
Highest counting speed | Contact input: 50 c/s. Solid-state: 500 c/s, 5 kc/s, 50 kc/s selectable (ON/OFF ratio=1:1) |
Input signal | ― |
Output | Control output | SPDT: 250 VAC, 2 A (125 VA max.) NPN: 100 mA (40 V) max. Residual voltage: 1 V max. |
Control output | One-shot output time | 0.01 to 9.99 sec. variable |
Solid-state | Contact: 13 ms (50 c/s mode) 4 ms (500 c/s mode) 4 ms (5 kc/s mode) 4 ms (50 kc/s mode) |
DC output | 12 VDC ±10%, 100 mA max. |
Rating | Power voltage | 100 to 240 VAC ±10 %, 50/60 Hz |
Power consumption | 12VA or less |
Environmental resistance | Insulation resistance | 100 MΩ min. at 500 VDC megger (across terminal and housing) |
Noise resistance | Square-wave noise by noise simulator: 1 kV p-p, 1 µs (across power terminals) |
Environmental resistance | Ambient temperature | 0 to +50 °C |
Relative humidity | 35 to 85 % RH (No condensation) |
Withstand voltage | 500 VAC, for 1 minute (across external AC terminal) |
Vibration resistance | 10 to 55 Hz, Double amplitude 0.75 mm, 2 hours in each of the X, Y, and Z directions |
Shock resistance | 100 m/s2, 3 times in each of the X, Y, and Z directions |
Weight | Approx. 320 g |
*1 Display uses the zero suppression method. |