Model | BL-1370 |
Type | Long-range |
Type | Reading direction | Front |
Scanning method | Single |
Laser | Light source | Visible red semiconductor laser (660 nm wavelength) |
Control output | 85 µW |
Pulse duration | 112 µs |
Laser class | Class 2 Laser Product (IEC60825-1, FDA (CDRH) Part1040.10*1) |
Reading | Supported codes | CODE 39, ITF, Industrial 2of5, Standard 2of5, COOP 2of5, NW-7 (Codabar), CODE 128, GS1-128, CODE 93, EAN/UPC, GS1 DataBar |
Number of readable digits | 74 digits (148 digits with CODE 128 start character C) |
Readable bar width | 0.15 mm to |
Reading distance | 160 to 600 mm*2 (1.0 mm narrow bar width) |
Focal point | 230 mm |
Largest readable label width | 404 mm*2 (420 mm distance, 1.0 mm narrow bar width) |
PCS | 0.4 or more |
Scanning rate | 500 to 1,300 scans/second |
I/O specifications | Input terminals | Number of inputs | Two (IN1, IN2) |
Input format | non-voltage input (contact or solid-state) |
Output terminals | Number of outputs | Four (OUT1 through OUT4) |
Output | NPN open collector |
Rated load | 24 VDC, 30 mA |
Leakage current (at OFF) | 0.1 mA or less |
Residual voltage (at ON) | 0.5 V or less |
Serial interface | Communication method | Conforms to EIA, RS-232C |
Communication speed | 600, 1,200, 2,400, 4,800, 9,600, 19,200, 31,250, 38,400, 57,600, 115,200 bps |
Synchronisation between the transmitter and receiver | Asynchronous |
Data bit length | 7/8 bits |
Stop bit length | 1/2 bits |
Parity check | None/Even/Odd |
Rating | Power voltage | 5 VDC ±5 % |
Voltage consumption | 400 mA or less |
Environmental resistance | Enclosure rating | IP65 |
Ambient light | 10,000 lux (sunlight), 6,000 lux (Incandescent lamp) |
Ambient temperature | 0 to +45 °C |
Storage temperature | -20 to +60 °C |
Relative humidity | 35 to 85 % RH (No condensation) |
Operating environment | No dust or corrosive gas present |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions |
Weight | Approx. 115 g |
*1 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice. *2 Specifications for 500-scan/second operation Use the Limited Power Source defined in UL/IEC60950-1 to comply with UL/IEC60950-1. Internal body settings are written in the internal memory area (can be rewritten 100,000 times). |