KEYENCE
SJ-E060N
Bar Type Main Unit, Network Model 600 mm
Specifications:
Model | SJ-E060N |
Ion generation method | Corona discharge method |
Structure | Shockless resistor connection type |
Voltage application method/ applied voltage | Pulse AC method/±8,000 V |
Ion balance control method | Hi-Power I.C.C. method |
Ion balance | ±30 V |
Operating distance | 50 to 2,000 mm |
Communication feature | RS-485 communication/remote control communication |
Major features | Condition alarm, ion level alarm, and alarm output |
Air connection port | Rc 1/8 |
Air supply pressure | 0.1 to 0.5 MPa (recommended air pressure: 0.2 MPa)*1 |
Effective length | 680 mm*2 |
Total length | 560 mm |
No. of electrodes | 9 |
Rating | Power voltage | 24 to 36 VDC ±10 % |
Current consumption | 700 mA (at 24 V) or 500 mA (at 36 V) |
Overvoltage category | I |
Pollution degree | 2 |
Environmental resistance | Ambient temperature | 0 to +40 °C |
Relative humidity | 35 to 85 % RH (No condensation) |
Material | Electrode probe | Tungsten |
Body | ABS/PBT/PP/LCP/PPS/SPS/SUS |
Weight | 850 g |
*1 Contact us for details on this value when the air supply is opened and closed. *2 Elective length indicates the static elimination rangeat 50 mm operating distance. |